{"title":"Tags and Cell Markers","description":"\u003cp\u003eAccurately label and track cells, proteins, and other biological molecules with our versatile tags and cell markers. Our offerings include fluorescent proteins, biotinylation reagents, and immunocytochemistry kits, enabling you to visualize and study cellular processes.\u003c\/p\u003e","products":[{"product_id":"human-myelin-basic-protein-clia-kit","title":"Human Myelin Basic Protein Chemiluminescent Immunoassay Kit","description":"Human Myelin Basic Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Myelin Basic Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MBP in samples. No significant cross-reactivity or interference between Human MBP and analogues was observed. Innovative Research's Myelin Basic Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MBP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MBP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MBP. You can calculate the concentration of Human MBP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Myelin Basic Protein Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479526596,"sku":"IHUMBPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_05cb5012-dcb5-4376-ae6f-da75f7973e06.jpg?v=1740172922"},{"product_id":"human-actin-alpha-1-skeletal-muscle-clia-kit","title":"Human Actin Alpha 1 Skeletal Muscle Chemiluminescent Immunoassay Kit","description":"Human Actin Alpha 1, Skeletal Muscle Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Actin Alpha 1, Skeletal Muscle in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ACT?1 in samples. No significant cross-reactivity or interference between Human ACT?1 and analogues was observed. Innovative Research's Actin Alpha 1, Skeletal Muscle Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ACT?1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ACT?1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ACT?1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ACT?1. You can calculate the concentration of Human ACT?1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Actin Alpha 1, Skeletal Muscle Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813484409028,"sku":"IHUACTA1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9fc4037d-8b24-4c9c-a25f-38eee7ae2a1d.jpg?v=1740172975"},{"product_id":"human-activated-leukocyte-cell-adhesion-molecule-clia-kit","title":"Human Activated Leukocyte Cell Adhesion Molecule Chemiluminescent Immunoassay Kit","description":"Human Activated Leukocyte Cell Adhesion Molecule Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Activated Leukocyte Cell Adhesion Molecule in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ALCAM in samples. No significant cross-reactivity or interference between Human ALCAM and analogues was observed. Innovative Research's Activated Leukocyte Cell Adhesion Molecule Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ALCAM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ALCAM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ALCAM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ALCAM. You can calculate the concentration of Human ALCAM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Activated Leukocyte Cell Adhesion Molecule Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486145732,"sku":"IHUALCAMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d2a6a775-602c-40ef-8474-241aa382c9b9.jpg?v=1740173001"},{"product_id":"human-asialoglycoprotein-receptor-1-clia-kit","title":"Human Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay Kit","description":"Human Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Asialoglycoprotein Receptor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ASGR1 in samples. No significant cross-reactivity or interference between Human ASGR1 and analogues was observed. Innovative Research's Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ASGR1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ASGR1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ASGR1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ASGR1. You can calculate the concentration of Human ASGR1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Asialoglycoprotein Receptor 1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496860868,"sku":"IHUASGR1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_966da2c0-0a7e-4a6a-8d1c-9c3cebeb95d8.jpg?v=1740173138"},{"product_id":"human-tumor-marker-ca724-clia-kit","title":"Human Tumor Marker CA724 Chemiluminescent Immunoassay Kit","description":"Human Tumor Marker CA724 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Tumor Marker CA724 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CA724 in samples. No significant cross-reactivity or interference between Human CA724 and analogues was observed. Innovative Research's Tumor Marker CA724 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CA724. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CA724 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CA724, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CA724. You can calculate the concentration of Human CA724 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Tumor Marker CA724 Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813499318468,"sku":"IHUCA724KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c3845f55-5600-4fcf-ad30-f6ec8dbacedc.jpg?v=1740173189"},{"product_id":"human-mucin-2-clia-kit","title":"Human Mucin 2 Chemiluminescent Immunoassay Kit","description":"Human Mucin 2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Mucin 2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MUC2 in samples. No significant cross-reactivity or interference between Human MUC2 and analogues was observed. Innovative Research's Mucin 2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MUC2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MUC2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MUC2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MUC2. You can calculate the concentration of Human MUC2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Mucin 2 Reactivity: Human Range: 78.13 - 5000 pg\/mL Sensitivity: 46.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813501087940,"sku":"IHUMUC2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d4bdcedd-037c-4ca7-95f9-685c01507ac5.jpg?v=1740173204"},{"product_id":"human-carcinoembryonic-antigen-clia-kit","title":"Human Carcinoembryonic Antigen Chemiluminescent Immunoassay Kit","description":"Human Carcinoembryonic Antigen Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Carcinoembryonic Antigen in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CEA in samples. No significant cross-reactivity or interference between Human CEA and analogues was observed. Innovative Research's Carcinoembryonic Antigen Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CEA. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CEA and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CEA, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CEA. You can calculate the concentration of Human CEA in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Carcinoembryonic Antigen Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813501579460,"sku":"IHUCEAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_291cf1ad-f0b4-4a7f-ada0-e1d676691b4f.jpg?v=1740173211"},{"product_id":"human-neuron-specific-enolase-clia-kit","title":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit","description":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neuron-Specific Enolase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NSE in samples. No significant cross-reactivity or interference between Human NSE and analogues was observed. Innovative Research's Neuron-Specific Enolase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NSE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NSE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NSE. You can calculate the concentration of Human NSE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neuron-Specific Enolase Reactivity: Human Range: 0.47 - 30 ng\/mL Sensitivity: 0.28 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813512458436,"sku":"IHUNSEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d9adaf8b-5761-49e8-9fa5-e25e66895f52.jpg?v=1740173385"},{"product_id":"human-alpha-fodrin-clia-kit","title":"Human Alpha-Fodrin Chemiluminescent Immunoassay Kit","description":"Human Alpha-Fodrin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Alpha-Fodrin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human SPTAN1 in samples. No significant cross-reactivity or interference between Human SPTAN1 and analogues was observed. Innovative Research's Alpha-Fodrin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human SPTAN1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human SPTAN1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human SPTAN1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human SPTAN1. You can calculate the concentration of Human SPTAN1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Alpha-Fodrin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862997708996,"sku":"IHUSPTAN1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_73c19674-2216-4737-b08b-04e9334e73ec.jpg?v=1740173692"},{"product_id":"human-sirtuin-1-clia-kit","title":"Human Sirtuin 1 Chemiluminescent Immunoassay Kit","description":"Human Sirtuin 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Sirtuin 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human SIRT1 in samples. No significant cross-reactivity or interference between Human SIRT1 and analogues was observed. Innovative Research's Sirtuin 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human SIRT1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human SIRT1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human SIRT1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human SIRT1. You can calculate the concentration of Human SIRT1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Sirtuin 1 Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862998069444,"sku":"IHUSIRT1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_1ca452f3-b4f9-460e-966a-389b83f3c1c7.jpg?v=1740173696"},{"product_id":"human-endothelial-cell-specific-molecule-1-clia-kit","title":"Human Endothelial Cell Specific Molecule 1 Chemiluminescent Immunoassay Kit","description":"Human Endothelial Cell Specific Molecule 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Endothelial Cell Specific Molecule 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ESM1 in samples. No significant cross-reactivity or interference between Human ESM1 and analogues was observed. Innovative Research's Endothelial Cell Specific Molecule 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ESM1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ESM1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ESM1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ESM1. You can calculate the concentration of Human ESM1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Endothelial Cell Specific Molecule 1 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862999675076,"sku":"IHUESM1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_942e4d59-e962-4f0d-9a0d-275b6e577da5.jpg?v=1740173704"},{"product_id":"human-prostatic-acid-phosphatase-3-clia-kit","title":"Human Prostatic Acid Phosphatase 3 Chemiluminescent Immunoassay Kit","description":"Human Prostatic Acid Phosphatase 3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Prostatic Acid Phosphatase 3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ACP3\/PAP in samples. No significant cross-reactivity or interference between Human ACP3\/PAP and analogues was observed. Innovative Research's Prostatic Acid Phosphatase 3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ACP3\/PAP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ACP3\/PAP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ACP3\/PAP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ACP3\/PAP. You can calculate the concentration of Human ACP3\/PAP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Prostatic Acid Phosphatase 3 Reactivity: Human Range: 0.16 - 10 ng\/mL Sensitivity: 0.09 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863027822788,"sku":"IHUACP3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_61d68a6a-14db-47df-8d01-8a5e86869190.jpg?v=1740173847"},{"product_id":"human-glial-fibrillary-acidic-protein-clia-kit","title":"Human Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay Kit","description":"Human Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glial Fibrillary Acidic Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GFAP in samples. No significant cross-reactivity or interference between Human GFAP and analogues was observed. Innovative Research's Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GFAP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GFAP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GFAP. You can calculate the concentration of Human GFAP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glial Fibrillary Acidic Protein Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863032312004,"sku":"IHUGFAPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_092652aa-167b-4967-a678-a5d5d1ee5887.jpg?v=1740173871"},{"product_id":"human-ubiquitin-carboxyl-terminal-hydrolase-l1-clia-kit","title":"Human Ubiquitin Carboxyl Terminal Hydrolase L1 Chemiluminescent Immunoassay Kit","description":"Human Ubiquitin Carboxyl Terminal Hydrolase L1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Ubiquitin Carboxyl Terminal Hydrolase L1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human UCHL1 in samples. No significant cross-reactivity or interference between Human UCHL1 and analogues was observed. Innovative Research's Ubiquitin Carboxyl Terminal Hydrolase L1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human UCHL1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human UCHL1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human UCHL1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human UCHL1. You can calculate the concentration of Human UCHL1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Ubiquitin Carboxyl Terminal Hydrolase L1 Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863061737668,"sku":"IHUUCHL1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_6c2ac9f3-9b65-42dd-973e-cf9978975a03.jpg?v=1740174059"},{"product_id":"mouse-asialoglycoprotein-receptor-1-clia-kit","title":"Mouse Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay Kit","description":"Mouse Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Asialoglycoprotein Receptor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse ASGR1 in samples. No significant cross-reactivity or interference between Mouse ASGR1 and analogues was observed. Innovative Research's Asialoglycoprotein Receptor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse ASGR1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse ASGR1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse ASGR1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse ASGR1. You can calculate the concentration of Mouse ASGR1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Asialoglycoprotein Receptor 1 Reactivity: Mouse Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863084806340,"sku":"IMSASGR1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_7982b115-05c6-42ec-8933-661d6c693c3f.jpg?v=1740174235"},{"product_id":"mouse-bone-alkaline-phosphatase-clia-kit","title":"Mouse Bone Alkaline Phosphatase Chemiluminescent Immunoassay Kit","description":"Mouse Bone Alkaline Phosphatase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bone Alkaline Phosphatase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse BALP in samples. No significant cross-reactivity or interference between Mouse BALP and analogues was observed. Innovative Research's Bone Alkaline Phosphatase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse BALP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse BALP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse BALP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse BALP. You can calculate the concentration of Mouse BALP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bone Alkaline Phosphatase Reactivity: Mouse Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904645836996,"sku":"IMSBALPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_24a5d4a4-8e73-4cec-a31e-ba4c6cb1a95c.jpg?v=1740174264"},{"product_id":"mouse-glial-fibrillary-acidic-protein-clia-kit","title":"Mouse glial fibrillary acidic protein Chemiluminescent Immunoassay Kit","description":"Mouse glial fibrillary acidic protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring glial fibrillary acidic protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse GFAP in samples. No significant cross-reactivity or interference between Mouse GFAP and analogues was observed. Innovative Research's glial fibrillary acidic protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse GFAP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse GFAP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse GFAP. You can calculate the concentration of Mouse GFAP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: glial fibrillary acidic protein Reactivity: Mouse Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904669790404,"sku":"IMSGFAPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_73d8e836-1f96-4157-875a-6d7a595cb946.jpg?v=1740174373"},{"product_id":"mouse-heat-shock-protein-60-clia-kit","title":"Mouse Heat Shock Protein 60 Chemiluminescent Immunoassay Kit","description":"Mouse Heat Shock Protein 60 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Heat Shock Protein 60 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse HSP-60 in samples. No significant cross-reactivity or interference between Mouse HSP-60 and analogues was observed. Innovative Research's Heat Shock Protein 60 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse HSP-60. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse HSP-60 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse HSP-60, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse HSP-60. You can calculate the concentration of Mouse HSP-60 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Heat Shock Protein 60 Reactivity: Mouse Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904674640068,"sku":"IMSHSP60KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_428a6e38-ce74-406b-a213-45206dbd0efb.jpg?v=1740174394"},{"product_id":"mouse-lysozyme-clia-kit","title":"Mouse Lysozyme Chemiluminescent Immunoassay Kit","description":"Mouse Lysozyme Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Lysozyme in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse LZM in samples. No significant cross-reactivity or interference between Mouse LZM and analogues was observed. Innovative Research's Lysozyme Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse LZM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse LZM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse LZM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse LZM. You can calculate the concentration of Mouse LZM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Lysozyme Reactivity: Mouse Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904696561860,"sku":"IMSLYZKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_3f3b85ac-acd0-4802-b6e1-e79e9449dad1.jpg?v=1740174463"},{"product_id":"mouse-myelin-basic-protein-clia-kit","title":"Mouse Myelin Basic Protein Chemiluminescent Immunoassay Kit","description":"Mouse Myelin Basic Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Myelin Basic Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse MBP in samples. No significant cross-reactivity or interference between Mouse MBP and analogues was observed. Innovative Research's Myelin Basic Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse MBP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse MBP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse MBP. You can calculate the concentration of Mouse MBP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Myelin Basic Protein Reactivity: Mouse Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904699904196,"sku":"IMSMBPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_ed2df206-dd48-42cb-8d0a-948fd392ee46.jpg?v=1740174475"},{"product_id":"rat-calreticulin-clia-kit","title":"Rat Calreticulin Chemiluminescent Immunoassay Kit","description":"Rat Calreticulin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Calreticulin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat CRT in samples. No significant cross-reactivity or interference between Rat CRT and analogues was observed. Innovative Research's Calreticulin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat CRT. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat CRT and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat CRT, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat CRT. You can calculate the concentration of Rat CRT in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Calreticulin Reactivity: Rat Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904741421252,"sku":"IRTCRTKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_f528edc5-4af3-4e32-a417-c35b21c9b8b6.jpg?v=1740174642"},{"product_id":"rat-chromogranin-a-clia-kit","title":"Rat Chromogranin A Chemiluminescent Immunoassay Kit","description":"Rat Chromogranin A Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Chromogranin A in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat CHGA in samples. No significant cross-reactivity or interference between Rat CHGA and analogues was observed. Innovative Research's Chromogranin A Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat CHGA. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat CHGA and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat CHGA, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat CHGA. You can calculate the concentration of Rat CHGA in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Chromogranin A Reactivity: Rat Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904747286724,"sku":"IRTCGAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_922ba5c3-5cfc-48ad-9bae-0bab11727895.jpg?v=1740174668"},{"product_id":"rat-heat-shock-protein-60-clia-kit","title":"Rat Heat Shock Protein 60 Chemiluminescent Immunoassay Kit","description":"Rat Heat Shock Protein 60 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Heat Shock Protein 60 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat HSP-60 in samples. No significant cross-reactivity or interference between Rat HSP-60 and analogues was observed. Innovative Research's Heat Shock Protein 60 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat HSP-60. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat HSP-60 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat HSP-60, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat HSP-60. You can calculate the concentration of Rat HSP-60 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Heat Shock Protein 60 Reactivity: Rat Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945485021380,"sku":"IRTHSP60KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_f7400c00-7d86-4606-94f8-67716b75980f.jpg?v=1740174762"},{"product_id":"rat-glial-fibrillary-acidic-protein-clia-kit","title":"Rat Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay Kit","description":"Rat Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glial Fibrillary Acidic Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat GFAP in samples. No significant cross-reactivity or interference between Rat GFAP and analogues was observed. Innovative Research's Glial Fibrillary Acidic Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat GFAP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat GFAP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat GFAP. You can calculate the concentration of Rat GFAP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glial Fibrillary Acidic Protein Reactivity: Rat Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945509859524,"sku":"IRTGFAPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_3284e426-afcb-4513-8e26-849f19a7a995.jpg?v=1740174959"},{"product_id":"mouse-anti-human-beta-tubulin-monoclonal-clone-3l2","title":"Mouse Anti Human Beta Tubulin Monoclonal Clone 3L2","description":"\u003cp\u003eMouse Anti Human Beta Tubulin Monoclonal Clone 3L2 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e TUBB3\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eTUBB3,the class III beta tubulin or Tuj1,is selectively expressed in testis and neurons of the central and peripheral nervous system. It has been widely used as a marker for neurons. Aberrant expression of TUBB3 has also been found in various tumors of non-neural origin and can be used as a biomarker for cancer aggressiveness and a marker for the tendency to respond poorly to chemotherapy. This antibody is specific to TUBB3 but not cross-react with other tubulin isoforms.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966241255620,"sku":"IMSAMLTUBB33L2C120UL","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_59035c41-1495-43f9-923a-d2153c9edfe6.jpg?v=1740083859"},{"product_id":"mouse-anti-human-beta-tubulin-monoclonal-clone-4a6","title":"Mouse Anti Human Beta Tubulin Monoclonal Clone 4A6","description":"\u003cp\u003eMouse Anti Human Beta Tubulin Monoclonal Clone 4A6 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e TUBB3\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eTUBB3,the class III beta tubulin or Tuj1,is selectively expressed in testis and neurons of the central and peripheral nervous system. It has been widely used as a marker for neurons. Aberrant expression of TUBB3 has also been found in various tumors of non-neural origin and can be used as a biomarker for cancer aggressiveness and a marker for the tendency to respond poorly to chemotherapy. This antibody is specific to TUBB3 but not cross-react with other tubulin isoforms.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966241321156,"sku":"IMSAMLTUBB34A6C120UL","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_570cc904-2f94-4766-b263-df9c40a7cdb5.jpg?v=1740083860"},{"product_id":"mouse-anti-human-beta-tubulin-monoclonal-clone-8b2","title":"Mouse Anti Human Beta Tubulin Monoclonal Clone 8B2","description":"\u003cp\u003eMouse Anti Human Beta Tubulin Monoclonal Clone 8B2 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat,Monkey,Chicken,Dog,Hamster,Rabbit,Sheep,Insect,Yeast\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e TUBB3\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThere are five tubulins in human cells: alpha, beta, gamma, delta, and epsilon. Tubulins are conserved across species. They form heterodimers, which multimerize to form a microtubule filament. An alpha and beta tubulin heterodimer is the basic structural unit of microtubules. The heterodimer does not come apart, once formed. The alpha and beta tubulins, which are each about 55 kDa MW, are homologous but not identical. Alpha, beta, and gamma tubulins have all been used as loading controls. Tubulin expression may vary according to resistance to antimicrobial and antimitotic drugs.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,IHC-p,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966241452228,"sku":"IMSAMLTUBB38B2C120UL","price":258.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_ef555dfd-8c67-4432-a9dd-848aed3cd51e.jpg?v=1740083862"},{"product_id":"mouse-anti-human-eno2-monoclonal-clone-2k3","title":"Mouse Anti Human ENO2 Monoclonal Clone 2K3","description":"\u003cp\u003eMouse Anti Human ENO2 Monoclonal Clone 2K3 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e ENO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHas neurotrophic and neuroprotective properties on a broad spectrum of central nervous system (CNS) neurons. Binds, in a calcium-dependent manner, to cultured neocortical neurons and promotes cell survival\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,IHC-p,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966242336964,"sku":"IMSAMLENO22K3C120UL","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_27dcfd02-87d9-4434-bbe2-74725af0fcbd.jpg?v=1740083872"},{"product_id":"mouse-anti-mouse-gfap-monoclonal-clone-2b12f1","title":"Mouse Anti Mouse GFAP Monoclonal Clone 2B12F1","description":"\u003cp\u003eMouse Anti Mouse GFAP Monoclonal Clone 2B12F1 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide, 1% BSA and 50% glycerol, pH7.4 This antibody has been purified using Affinity purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e GFAP\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e KLH conjugated Synthetic peptide corresponding to Mouse GFAP\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eGFAP (Glial fibrillary acidic protein ),an intermediate-filament (IF) protein ,is specifically expressed in cells of astroglial lineage and is widely used to mark the astroglia in the brain. It is  also used as a marker for intracranial and intraspinal tumors arising from astrocytes.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,IHC,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966245253316,"sku":"IMSAMLGFAP2B12F1C120UL","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_5efac8de-8d1d-4d53-b297-5a0e371f847c.jpg?v=1740083911"},{"product_id":"mouse-anti-mouse-gfap-monoclonal-clone-3h1","title":"Mouse Anti Mouse GFAP Monoclonal Clone 3H1","description":"\u003cp\u003eMouse Anti Mouse GFAP Monoclonal Clone 3H1 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e GFAP\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis gene encodes one of the major intermediate filament proteins of mature astrocytes. It is used as a marker to distinguish astrocytes from other glial cells during development. Mutations in this gene cause Alexander disease, a rare disorder of astrocytes in the central nervous system. Alternative splicing results in multiple transcript variants encoding distinct isoforms.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,IHC-p,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966245318852,"sku":"IMSAMLGFAP3H1C120UL","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_db810b0c-1958-4410-92db-623053602187.jpg?v=1740083912"},{"product_id":"human-cnx-elisa-kit","title":"Human CNX ELISA Kit","description":"Human CNX Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring CNX in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human CNX. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CNX and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CNX, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human CNX. You can calculate the concentration of Human CNX in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: CNX Reactivity: Human Range: 0.63 - 40ng\/mL Sensitivity: 0.38ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236038222020,"sku":"IHUCANXKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_2674a075-008a-479b-950f-7922f11f746c.jpg?v=1739978581"},{"product_id":"human-chga-elisa-kit","title":"Human CHGA ELISA Kit","description":"Human CHGA Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring CHGA in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human CHGA. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CHGA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CHGA, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human CHGA. You can calculate the concentration of Human CHGA in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: CHGA Reactivity: Human Range: 62.5 - 4000pg\/mL Sensitivity: 37.5pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236040548548,"sku":"IHUCHGAKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_2dd0a0f2-6b4e-41f0-81c0-719b68e73541.jpg?v=1739978604"},{"product_id":"human-nse-elisa-kit","title":"Human NSE ELISA Kit","description":"Human NSE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring NSE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human NSE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NSE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human NSE. You can calculate the concentration of Human NSE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: NSE Reactivity: Human Range: 2.34 - 150ng\/mL Sensitivity: 1.4ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236051984580,"sku":"IHUENO2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_954e24c7-812c-40fa-bb5f-6ee1abab8b70.jpg?v=1739978704"},{"product_id":"mouse-nse-elisa-kit","title":"Mouse NSE ELISA Kit","description":"Mouse NSE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring NSE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Mouse NSE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse NSE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Mouse NSE. You can calculate the concentration of Mouse NSE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: NSE Reactivity: Mouse Range: 78.13 - 5000pg\/mL Sensitivity: 46.88pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236052082884,"sku":"IMSENO2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_5dc8f077-4c02-469d-a347-338d131cb033.jpg?v=1739978705"},{"product_id":"rat-nse-elisa-kit","title":"Rat NSE ELISA Kit","description":"Rat NSE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring NSE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rat NSE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat NSE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rat NSE. You can calculate the concentration of Rat NSE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: NSE Reactivity: Rat Range: 0.31 - 20ng\/mL Sensitivity: 0.19ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236052148420,"sku":"IRTENO2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_f0631ba7-b1aa-4b18-bf85-daaf282b147c.jpg?v=1739978706"},{"product_id":"human-fgfr4-elisa-kit","title":"Human FGFR4 ELISA Kit","description":"Human FGFR4 Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring FGFR4 in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human FGFR4. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FGFR4 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FGFR4, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human FGFR4. You can calculate the concentration of Human FGFR4 in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: FGFR4 Reactivity: Human Range: 78.13 - 5000pg\/mL Sensitivity: 46.88pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236055883972,"sku":"IHUFGFR4KT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_a9bb948c-317f-42cd-92cc-c8f2dad163cc.jpg?v=1739978730"},{"product_id":"human-gfap-elisa-kit","title":"Human GFAP ELISA Kit","description":"Human GFAP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring GFAP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human GFAP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GFAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human GFAP. You can calculate the concentration of Human GFAP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: GFAP Reactivity: Human Range: 15.63 - 1000pg\/mL Sensitivity: 9.38pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236059291844,"sku":"IHUGFAPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_2a89ee4b-c74b-44ad-9ba5-f04fc15c9bd5.jpg?v=1739978761"},{"product_id":"mouse-gfap-elisa-kit","title":"Mouse GFAP ELISA Kit","description":"Mouse GFAP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring GFAP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Mouse GFAP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse GFAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Mouse GFAP. You can calculate the concentration of Mouse GFAP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: GFAP Reactivity: Mouse Range: 15.63 - 1000pg\/mL Sensitivity: 9.38pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236059390148,"sku":"IMSGFAPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_7afa712f-ab76-4ae5-97f9-c826879197a3.jpg?v=1739978762"},{"product_id":"rat-gfap-elisa-kit","title":"Rat GFAP ELISA Kit","description":"Rat GFAP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring GFAP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rat GFAP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat GFAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rat GFAP. You can calculate the concentration of Rat GFAP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: GFAP Reactivity: Rat Range: 0.31 - 20ng\/mL Sensitivity: 0.19ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236059553988,"sku":"IRTGFAPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_ea0a316a-ee59-4541-8d39-2886d3bbf003.jpg?v=1739978763"},{"product_id":"monkey-gfap-elisa-kit","title":"MonKey GFAP ELISA Kit","description":"MonKey GFAP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring GFAP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to MonKey GFAP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for MonKey GFAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain MonKey GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of MonKey GFAP. You can calculate the concentration of MonKey GFAP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: GFAP Reactivity: MonKey Range: 0.63 - 40ng\/mL Sensitivity: 0.38ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236059685060,"sku":"IMNGFAPKT","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_29393297-9529-46eb-86fb-40dfe994993f.jpg?v=1739978764"},{"product_id":"porcine-gfap-elisa-kit","title":"Porcine GFAP ELISA Kit","description":"Porcine GFAP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring GFAP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Porcine GFAP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Porcine GFAP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Porcine GFAP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Porcine GFAP. You can calculate the concentration of Porcine GFAP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: GFAP Reactivity: Porcine Range: 0.313 - 20ng\/mL Sensitivity: 0.188ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236059750596,"sku":"IPCGFAPKT","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_107e292c-cd81-4bac-aae2-f70840786a31.jpg?v=1739978766"},{"product_id":"human-irs1-elisa-kit","title":"Human IRS1 ELISA Kit","description":"Human IRS1 Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring IRS1 in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human IRS1. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IRS1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IRS1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human IRS1. You can calculate the concentration of Human IRS1 in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: IRS1 Reactivity: Human Range: 0.16 - 10ng\/mL Sensitivity: 0.09ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236064633028,"sku":"IHUIRS1KT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_0edef0f3-dca1-4558-8772-122a48498042.jpg?v=1739978828"},{"product_id":"mouse-psa-elisa-kit","title":"Mouse PSA ELISA Kit","description":"Mouse PSA Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring PSA in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Mouse PSA. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse PSA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse PSA, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Mouse PSA. You can calculate the concentration of Mouse PSA in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: PSA Reactivity: Mouse Range: 0.16 - 10ng\/mL Sensitivity: 0.09ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236065255620,"sku":"IMSKLK1B3KT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_be4db37f-b461-4372-a1cd-fac992932e3c.jpg?v=1739978839"},{"product_id":"human-psa-elisa-kit","title":"Human PSA ELISA Kit","description":"Human PSA Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring PSA in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human PSA. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human PSA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human PSA, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human PSA. You can calculate the concentration of Human PSA in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: PSA Reactivity: Human Range: 0.31 - 20ng\/mL Sensitivity: 0.19ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236065288388,"sku":"IHUKLK3KT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_3e48d494-f7b8-4a4b-9c56-95b85efe7584.jpg?v=1739978840"},{"product_id":"human-mbp-elisa-kit","title":"Human MBP ELISA Kit","description":"Human MBP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring MBP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human MBP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MBP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human MBP. You can calculate the concentration of Human MBP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: MBP Reactivity: Human Range: 15.63 - 1000pg\/mL Sensitivity: 9.38pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236066762948,"sku":"IHUMBPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_d3da2089-655c-4d99-878f-ff14db7e9843.jpg?v=1739978874"},{"product_id":"mouse-mbp-elisa-kit","title":"Mouse MBP ELISA Kit","description":"Mouse MBP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring MBP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Mouse MBP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse MBP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Mouse MBP. You can calculate the concentration of Mouse MBP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: MBP Reactivity: Mouse Range: 0.16 - 10ng\/mL Sensitivity: 0.09ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236066795716,"sku":"IMSMBPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_52decd40-09d4-4950-a65c-1041bede4b62.jpg?v=1739978875"},{"product_id":"rat-mbp-elisa-kit","title":"Rat MBP ELISA Kit","description":"Rat MBP Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring MBP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rat MBP. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat MBP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rat MBP. You can calculate the concentration of Rat MBP in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: MBP Reactivity: Rat Range: 0.16 - 10ng\/mL Sensitivity: 0.09ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236066828484,"sku":"IRTMBPKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_69696011-c154-4d1a-9095-4c66fa511b12.jpg?v=1739978876"},{"product_id":"mouse-cnp-elisa-kit","title":"Mouse CNP ELISA Kit","description":"Mouse CNP Competitive ELISA Kit from Innovative Research is a highly sensitive competitive enzyme-linked immunoassay (Competitive ELISA) for measuring CNP in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Competitive ELISA Kit uses the Competitive-Competitive ELISA principle. The micro Competitive ELISA plate provided in this Kit has been pre-coated with Mouse CNP. During the reaction, Mouse CNP in samples or Standard competes with a fixed amount of Mouse CNP on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Mouse CNP. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The concentration of Mouse CNP in the samples is then determined by comparing the OD of the samples to the standard curve.More Details: Detection Target: CNP Reactivity: Mouse Range: 15.63 - 1000pg\/mL Sensitivity: 9.38pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236068761796,"sku":"IMSNPPCKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_e3d85de7-dd0b-44dd-9ef9-5b5351740d31.jpg?v=1739978926"},{"product_id":"human-pfn1-elisa-kit","title":"Human PFN1 ELISA Kit","description":"Human PFN1 Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring PFN1 in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human PFN1. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human PFN1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human PFN1, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human PFN1. You can calculate the concentration of Human PFN1 in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: PFN1 Reactivity: Human Range: 78.13 - 5000pg\/mL Sensitivity: 46.88pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236070695108,"sku":"IHUPFN1KT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_d9371564-1715-480b-95ee-9dd18e9d6c88.jpg?v=1739978970"},{"product_id":"rat-psa-elisa-kit","title":"Rat PSA ELISA Kit","description":"Rat PSA Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring PSA in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rat PSA. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat PSA and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat PSA, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rat PSA. You can calculate the concentration of Rat PSA in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: PSA Reactivity: Rat Range: 0.16 - 10ng\/mL Sensitivity: 0.09ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236072399044,"sku":"IRTPSAKT","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_5631d08c-d8cf-4e68-b94f-b9713e6a0e4e.jpg?v=1739979004"}],"url":"https:\/\/www.innov-research.com\/collections\/tags-and-cell-markers.oembed?page=4","provider":"Innovative Research","version":"1.0","type":"link"}