{"title":"Neuroscience","description":"\u003cp\u003eNeurogenerative diseases result from progressive damage to cells and nervous system connections. The desire for less invasive diagnostics has continued to spur interest in blood-based biomarkers and furthered the use of imaging biomarkers as tools for research, such as hippocampal volume and PET imaging as tools for research. Other trending studies focus on the use of knockout models to isolate mutated genes to further characterize them. \u003c\/p\u003e\n\u003cp\u003eFrom polyclonal and monoclonal antibodies to Apo-E and amyloid precursor protein ELISA kits, to BACE1 and \u003cspan data-mce-fragment=\"1\"\u003eAlpha-synuclein\u003c\/span\u003e recombinant proteins and biologicals including disease state plasma and serum, we offer a growing library of the research tools needed to push your work forward.\u003c\/p\u003e","products":[{"product_id":"single-donor-human-cerebrospinal-fluid","title":"Single Donor Human Cerebrospinal Fluid (CSF) Vial","description":"\u003cp\u003eSingle Donor Human Cerebrospinal Fluid (CSF) Vial from Innovative Research is collected from remnant samples from living individual donors. Cerebrospinal fluid (CSF) is a clear, colorless bodily fluid produced in the choroid plexus of the brain. It acts as a cushion or buffer for the cortex, providing basic mechanical and immunological protection to the brain inside the skull, serving a vital function in cerebral auto-regulation of cerebral blood flow.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.dropbox.com\/s\/gme2y3x7oh48l6e\/HumanBiologicalFluids_SDS.pdf?dl=1\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eDownload Sample Safety Data Sheet\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.dropbox.com\/s\/uvb11x62n2taffb\/IRHUCSFS.pdf?dl=1\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003ePlease note – Approximate volume of 0.5 to 1mL per vial\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"Vial","offer_id":21258850664528,"sku":"IRHUCSFSVIAL","price":451.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/b6f4b53a-fa55-4133-a3a3-6e034a5acbc3_9fff92c5-5517-4033-9978-5831d9c19de6.jpg?v=1739974640"},{"product_id":"pooled-human-cerebrospinal-fluid","title":"Pooled Human Cerebrospinal Fluid (CSF)","description":"\u003cp\u003ePooled Human Cerebrospinal Fluid (CSF) from Innovative Research is collected from remnant samples from living individual donors and pooled. Cerebrospinal fluid (CSF) is a clear and colorless bodily fluid produced in the choroid plexus of the brain. It acts as a cushion or buffer for the cortex, providing a basic mechanical and immunological protection to the brain inside the skull, serving a vital function in cerebral auto regulation of cerebral blood flow.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/www.dropbox.com\/s\/gme2y3x7oh48l6e\/HumanBiologicalFluids_SDS.pdf?dl=1\" target=\"_blank\"\u003eDownload Sample Safety Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePlease note – this product replaces our old product number IPLA-CSFP (same product, new number).\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"1ml","offer_id":21258850730064,"sku":"IRHUCSF1ML","price":264.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/b6f4b53a-fa55-4133-a3a3-6e034a5acbc3_4cc95809-7d3e-4ec7-9224-01ded0ce0dfc.jpg?v=1739974641"},{"product_id":"synthetic-human-cerebrospinal-fluid-csf","title":"Synthetic Human Cerebrospinal Fluid (CSF)","description":"Synthetic Human Cerebrospinal Fluid (CSF) from Innovative Research has been prepared to closely resemble natural CSF. This product is sterile, formulated using high purity water and analytical-grade reagents, and is 0.2 Ąm filtered. Synthetic CSF does not contain neurotransmitters and electrolyte levels closely match those of natural CSF with final ion concentrations of 150 mM Na, 3.0 mM K, 1.4 mM Ca, 0.8 mM Mg, 1.0 mM P, and 155 mM Cl. The final makeup of this product closely mirrors that of brain interstitial fluid, and the pH can be easily adjusted using HCl or NaOH to meet your exact research application. This product is useful as a control and can replace human and animal samples for a variety of in vitro applications, including but not limited to measuring CSF absorption, use as a general infusate or perfusate, use as a sterile dilutent, use as a flushing fluid for molecule delivery, and in electrophysiology research to maintain osmolarity and\/or buffer pH at physiological levels. Larger volumes available upon request. More Details: Storage Conditions: -20 C; At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"25ml","offer_id":32088197169232,"sku":"IRHUCSFSYT25ML","price":205.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/b6f4b53a-fa55-4133-a3a3-6e034a5acbc3_b49c78ee-62a4-4de3-8cc5-5fe685880a1a.jpg?v=1739974712"},{"product_id":"human-adiponectin-clia-kit","title":"Human Adiponectin Chemiluminescent Immunoassay Kit","description":"Human Adiponectin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adiponectin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADP\/Acrp30 in samples. No significant cross-reactivity or interference between Human ADP\/Acrp30 and analogues was observed. Innovative Research's Adiponectin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADP\/Acrp30. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADP\/Acrp30 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADP\/Acrp30, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADP\/Acrp30. You can calculate the concentration of Human ADP\/Acrp30 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adiponectin Reactivity: Human Range: 0.78 - 50 ng\/mL Sensitivity: 0.47 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813469139140,"sku":"IHUADPNKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_07ea66dd-aa1a-451b-b76b-63cfebced492.jpg?v=1740172756"},{"product_id":"human-interleukin-6-clia-kit","title":"Human Interleukin 6 Chemiluminescent Immunoassay Kit","description":"Human Interleukin 6 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Interleukin 6 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IL-6 in samples. No significant cross-reactivity or interference between Human IL-6 and analogues was observed. Innovative Research's Interleukin 6 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IL-6. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-6 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-6, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IL-6. You can calculate the concentration of Human IL-6 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Interleukin 6 Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813476806852,"sku":"IHUIL6KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9d0de6ed-45ae-4d71-a816-8ce171421444.jpg?v=1740172872"},{"product_id":"human-leptin-clia-kit","title":"Human Leptin Chemiluminescent Immunoassay Kit","description":"Human Leptin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Leptin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human LEP in samples. No significant cross-reactivity or interference between Human LEP and analogues was observed. Innovative Research's Leptin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human LEP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human LEP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human LEP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human LEP. You can calculate the concentration of Human LEP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Leptin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813477724356,"sku":"IHULEPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_11a6bb8d-808b-4cdb-9ff1-52d922654284.jpg?v=1740172886"},{"product_id":"human-glucagon-like-peptide-1-clia-kit","title":"Human Glucagon Like Peptide 1 Chemiluminescent Immunoassay Kit","description":"Human Glucagon Like Peptide 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glucagon Like Peptide 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GLP-1 in samples. No significant cross-reactivity or interference between Human GLP-1 and analogues was observed. Innovative Research's Glucagon Like Peptide 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GLP-1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GLP-1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GLP-1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GLP-1. You can calculate the concentration of Human GLP-1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glucagon Like Peptide 1 Reactivity: Human Range: 78.13 - 5000 pg\/mL Sensitivity: 46.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479133380,"sku":"IHUGLP1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_da6db2fb-88a3-4ea8-bf8e-fc438459e845.jpg?v=1740172909"},{"product_id":"human-myelin-basic-protein-clia-kit","title":"Human Myelin Basic Protein Chemiluminescent Immunoassay Kit","description":"Human Myelin Basic Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Myelin Basic Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MBP in samples. No significant cross-reactivity or interference between Human MBP and analogues was observed. Innovative Research's Myelin Basic Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MBP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MBP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MBP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MBP. You can calculate the concentration of Human MBP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Myelin Basic Protein Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479526596,"sku":"IHUMBPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_05cb5012-dcb5-4376-ae6f-da75f7973e06.jpg?v=1740172922"},{"product_id":"human-ferritin-clia-kit","title":"Human Ferritin Chemiluminescent Immunoassay Kit","description":"Human Ferritin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Ferritin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human FE in samples. No significant cross-reactivity or interference between Human FE and analogues was observed. Innovative Research's Ferritin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human FE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human FE. You can calculate the concentration of Human FE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Ferritin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479755972,"sku":"IHUFTKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_57949cee-c187-4032-b94c-8c93f48522b1.jpg?v=1740172928"},{"product_id":"human-acetylcholinesterase-clia-kit","title":"Human Acetylcholinesterase Chemiluminescent Immunoassay Kit","description":"Human Acetylcholinesterase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Acetylcholinesterase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AChE in samples. No significant cross-reactivity or interference between Human AChE and analogues was observed. Innovative Research's Acetylcholinesterase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AChE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AChE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AChE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AChE. You can calculate the concentration of Human AChE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Acetylcholinesterase Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813482049732,"sku":"IHUACHEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_eaedb716-243c-4260-a2d6-af6453b201df.jpg?v=1740172966"},{"product_id":"human-adrenomedullin-clia-kit","title":"Human Adrenomedullin Chemiluminescent Immunoassay Kit","description":"Human Adrenomedullin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adrenomedullin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADM in samples. No significant cross-reactivity or interference between Human ADM and analogues was observed. Innovative Research's Adrenomedullin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADM. You can calculate the concentration of Human ADM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adrenomedullin Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485293764,"sku":"IHUADMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9af33ab0-3060-4cf4-850e-710b93fb7e5f.jpg?v=1740172981"},{"product_id":"human-adrenergic-receptor-alpha-1a-clia-kit","title":"Human Adrenergic Receptor alpha-1A  Chemiluminescent Immunoassay Kit","description":"Human Adrenergic Receptor alpha-1A Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adrenergic Receptor alpha-1A in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADRA1A in samples. No significant cross-reactivity or interference between Human ADRA1A and analogues was observed. Innovative Research's Adrenergic Receptor alpha-1A Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADRA1A. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADRA1A and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADRA1A, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADRA1A. You can calculate the concentration of Human ADRA1A in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adrenergic Receptor alpha-1A Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485326532,"sku":"IHUADRA1AKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_63e2d677-afed-4788-937e-3b4c0bd81c2f.jpg?v=1740172982"},{"product_id":"human-total-advanced-glycosylation-end-product-specific-receptor-clia-kit","title":"Human Total Advanced Glycosylation End Product Specific Receptor Chemiluminescent Immunoassay Kit","description":"Human Total Advanced Glycosylation End Product Specific Receptor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Total Advanced Glycosylation End Product Specific Receptor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AGER in samples. No significant cross-reactivity or interference between Human AGER and analogues was observed. Innovative Research's Total Advanced Glycosylation End Product Specific Receptor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AGER. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGER and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGER, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AGER. You can calculate the concentration of Human AGER in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Total Advanced Glycosylation End Product Specific Receptor Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485719748,"sku":"IHUAGERKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_66ecc0df-4b95-494e-8eed-cd17062e4c7b.jpg?v=1740172994"},{"product_id":"human-agrin-clia-kit","title":"Human Agrin Chemiluminescent Immunoassay Kit","description":"Human Agrin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Agrin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AGRN in samples. No significant cross-reactivity or interference between Human AGRN and analogues was observed. Innovative Research's Agrin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AGRN. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGRN and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGRN, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AGRN. You can calculate the concentration of Human AGRN in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Agrin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485818052,"sku":"IHUAGRNKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_ae3beb2a-3a4e-4356-8437-2b206df2ea5e.jpg?v=1740172997"},{"product_id":"human-allograft-inflammatory-factor-1-clia-kit","title":"Human Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay Kit","description":"Human Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Allograft Inflammatory Factor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AIF1 in samples. No significant cross-reactivity or interference between Human AIF1 and analogues was observed. Innovative Research's Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AIF1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AIF1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AIF1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AIF1. You can calculate the concentration of Human AIF1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Allograft Inflammatory Factor 1 Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486112964,"sku":"IHUAIF1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_5b0aaa95-7615-4b05-863b-6425989a418c.jpg?v=1740173000"},{"product_id":"human-phosphorylated-adenosine-monophosphate-activated-protein-kinase-clia-kit","title":"Human Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay Kit","description":"Human Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Phosphorylated Adenosine Monophosphate Activated Protein Kinase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AMPK in samples. No significant cross-reactivity or interference between Human AMPK and analogues was observed. Innovative Research's Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AMPK. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AMPK and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AMPK, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AMPK. You can calculate the concentration of Human AMPK in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Phosphorylated Adenosine Monophosphate Activated Protein Kinase Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486375108,"sku":"IHUAMPKKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aebdfd56-d363-41c3-8974-7c13dfcdff2c.jpg?v=1740173009"},{"product_id":"human-cerebral-dopamine-neurotrophic-factor-clia-kit","title":"Human Cerebral Dopamine Neurotrophic Factor Chemiluminescent Immunoassay Kit","description":"Human Cerebral Dopamine Neurotrophic Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cerebral Dopamine Neurotrophic Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CDNF in samples. No significant cross-reactivity or interference between Human CDNF and analogues was observed. Innovative Research's Cerebral Dopamine Neurotrophic Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CDNF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CDNF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CDNF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CDNF. You can calculate the concentration of Human CDNF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cerebral Dopamine Neurotrophic Factor Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486964932,"sku":"IHUCDNFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_166e11d2-b54f-46b5-adca-a45552f94e57.jpg?v=1740173025"},{"product_id":"human-insulin-degrading-enzyme-clia-kit","title":"Human Insulin Degrading Enzyme Chemiluminescent Immunoassay Kit","description":"Human Insulin Degrading Enzyme Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin Degrading Enzyme in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IDE in samples. No significant cross-reactivity or interference between Human IDE and analogues was observed. Innovative Research's Insulin Degrading Enzyme Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IDE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IDE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IDE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IDE. You can calculate the concentration of Human IDE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin Degrading Enzyme Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813492895940,"sku":"IHUIDEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_42277037-d791-4593-8d93-58934672e9c0.jpg?v=1740173082"},{"product_id":"human-insulin-receptor-clia-kit","title":"Human Insulin Receptor Chemiluminescent Immunoassay Kit","description":"Human Insulin Receptor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin Receptor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human INSR in samples. No significant cross-reactivity or interference between Human INSR and analogues was observed. Innovative Research's Insulin Receptor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human INSR. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human INSR and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human INSR, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human INSR. You can calculate the concentration of Human INSR in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin Receptor Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813495353540,"sku":"IHUINSRKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aea453ed-d006-459a-8ae3-a06850504680.jpg?v=1740173100"},{"product_id":"human-basic-fibroblast-growth-factor-clia-kit","title":"Human Basic Fibroblast Growth Factor Chemiluminescent Immunoassay Kit","description":"Human Basic Fibroblast Growth Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Basic Fibroblast Growth Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human bFGF\/FGF2 in samples. No significant cross-reactivity or interference between Human bFGF\/FGF2 and analogues was observed. Innovative Research's Basic Fibroblast Growth Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human bFGF\/FGF2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human bFGF\/FGF2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human bFGF\/FGF2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human bFGF\/FGF2. You can calculate the concentration of Human bFGF\/FGF2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Basic Fibroblast Growth Factor Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496238276,"sku":"IHUBFGFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c9106922-4268-46a4-b0cf-d489c5709944.jpg?v=1740173122"},{"product_id":"human-atp-binding-cassette-transporter-g1-clia-kit","title":"Human ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay Kit","description":"Human ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring ATP Binding Cassette Transporter G1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ABCG1 in samples. No significant cross-reactivity or interference between Human ABCG1 and analogues was observed. Innovative Research's ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ABCG1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ABCG1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ABCG1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ABCG1. You can calculate the concentration of Human ABCG1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: ATP Binding Cassette Transporter G1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497057476,"sku":"IHUABCG1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_ae20226d-3ebf-4f4e-bc71-007780d29685.jpg?v=1740173145"},{"product_id":"human-atp-binding-cassette-transporter-a1-clia-kit","title":"Human ATP-binding cassette transporter A1 Chemiluminescent Immunoassay Kit","description":"Human ATP-binding cassette transporter A1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring ATP-binding cassette transporter A1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ABCA1 in samples. No significant cross-reactivity or interference between Human ABCA1 and analogues was observed. Innovative Research's ATP-binding cassette transporter A1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ABCA1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ABCA1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ABCA1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ABCA1. You can calculate the concentration of Human ABCA1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: ATP-binding cassette transporter A1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497123012,"sku":"IHUABCA1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_71201e7b-9c87-4ef9-8361-0f7184aa6e22.jpg?v=1740173146"},{"product_id":"human-myelin-oligodendrocyte-glycoprotein-clia-kit","title":"Human Myelin Oligodendrocyte Glycoprotein Chemiluminescent Immunoassay Kit","description":"Human Myelin Oligodendrocyte Glycoprotein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Myelin Oligodendrocyte Glycoprotein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MOG in samples. No significant cross-reactivity or interference between Human MOG and analogues was observed. Innovative Research's Myelin Oligodendrocyte Glycoprotein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MOG. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MOG and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MOG, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MOG. You can calculate the concentration of Human MOG in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Myelin Oligodendrocyte Glycoprotein Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813498990788,"sku":"IHUMOGKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d5fd54c7-4402-47d8-93e2-47cd5e6ddaa7.jpg?v=1740173179"},{"product_id":"human-metallothionein-3-clia-kit","title":"Human Metallothionein 3 Chemiluminescent Immunoassay Kit","description":"Human Metallothionein 3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Metallothionein 3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MT3 in samples. No significant cross-reactivity or interference between Human MT3 and analogues was observed. Innovative Research's Metallothionein 3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MT3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MT3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MT3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MT3. You can calculate the concentration of Human MT3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Metallothionein 3 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813499252932,"sku":"IHUMT3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_2ca4883b-6da6-4fa3-949a-33692115158a.jpg?v=1740173187"},{"product_id":"human-cannabinoid-receptor-1-brain-clia-kit","title":"Human Cannabinoid Receptor 1 Brain Chemiluminescent Immunoassay Kit","description":"Human Cannabinoid Receptor 1, Brain Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cannabinoid Receptor 1, Brain in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CNR1 in samples. No significant cross-reactivity or interference between Human CNR1 and analogues was observed. Innovative Research's Cannabinoid Receptor 1, Brain Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CNR1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CNR1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CNR1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CNR1. You can calculate the concentration of Human CNR1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cannabinoid Receptor 1, Brain Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813501186244,"sku":"IHUCNR1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_2fb464af-8904-4c75-9449-277b11ccc106.jpg?v=1740173206"},{"product_id":"human-cathepsin-d-clia-kit","title":"Human Cathepsin D Chemiluminescent Immunoassay Kit","description":"Human Cathepsin D Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cathepsin D in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CTSD in samples. No significant cross-reactivity or interference between Human CTSD and analogues was observed. Innovative Research's Cathepsin D Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CTSD. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CTSD and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CTSD, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CTSD. You can calculate the concentration of Human CTSD in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cathepsin D Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813502267588,"sku":"IHUCTSDKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9e5f7130-6bc4-4579-af0a-9abf0450bc38.jpg?v=1740173227"},{"product_id":"human-cathepsin-k-clia-kit","title":"Human Cathepsin K Chemiluminescent Immunoassay Kit","description":"Human Cathepsin K Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cathepsin K in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CTSK in samples. No significant cross-reactivity or interference between Human CTSK and analogues was observed. Innovative Research's Cathepsin K Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CTSK. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CTSK and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CTSK, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CTSK. You can calculate the concentration of Human CTSK in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cathepsin K Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813502300356,"sku":"IHUCTSKKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_f2d74ea6-abfe-4719-aac3-05b47fdfbfa6.jpg?v=1740173228"},{"product_id":"human-neurofilament-light-polypeptide-clia-kit","title":"Human Neurofilament Light Polypeptide Chemiluminescent Immunoassay Kit","description":"Human Neurofilament, Light Polypeptide Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neurofilament, Light Polypeptide in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NEFL in samples. No significant cross-reactivity or interference between Human NEFL and analogues was observed. Innovative Research's Neurofilament, Light Polypeptide Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NEFL. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NEFL and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NEFL, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NEFL. You can calculate the concentration of Human NEFL in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neurofilament, Light Polypeptide Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813503217860,"sku":"IHUNEFLKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_3c31f684-b805-41f8-9383-0a3d73c1cf8f.jpg?v=1740173256"},{"product_id":"human-nitric-oxide-synthase-2-inducible-clia-kit","title":"Human Nitric Oxide Synthase 2 Inducible Chemiluminescent Immunoassay Kit","description":"Human Nitric Oxide Synthase 2, Inducible Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Nitric Oxide Synthase 2, Inducible in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NOS2\/iNOS in samples. No significant cross-reactivity or interference between Human NOS2\/iNOS and analogues was observed. Innovative Research's Nitric Oxide Synthase 2, Inducible Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NOS2\/iNOS. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NOS2\/iNOS and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NOS2\/iNOS, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NOS2\/iNOS. You can calculate the concentration of Human NOS2\/iNOS in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Nitric Oxide Synthase 2, Inducible Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813503447236,"sku":"IHUNOS2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_799eb504-0ab4-41db-bf76-209dd1edd12f.jpg?v=1740173262"},{"product_id":"human-nitric-oxide-synthase-3-endothelial-clia-kit","title":"Human Nitric Oxide Synthase 3 Endothelial Chemiluminescent Immunoassay Kit","description":"Human Nitric Oxide Synthase 3, Endothelial Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Nitric Oxide Synthase 3, Endothelial in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NOS3\/eNOS in samples. No significant cross-reactivity or interference between Human NOS3\/eNOS and analogues was observed. Innovative Research's Nitric Oxide Synthase 3, Endothelial Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NOS3\/eNOS. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NOS3\/eNOS and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NOS3\/eNOS, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NOS3\/eNOS. You can calculate the concentration of Human NOS3\/eNOS in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Nitric Oxide Synthase 3, Endothelial Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813503512772,"sku":"IHUNOS3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_7d7fb72d-33a2-4d81-a3b9-8472f6f55b5d.jpg?v=1740173265"},{"product_id":"human-collagen-type-vi-clia-kit","title":"Human Collagen Type VI Chemiluminescent Immunoassay Kit","description":"Human Collagen Type VI Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Collagen Type VI in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human COL6 in samples. No significant cross-reactivity or interference between Human COL6 and analogues was observed. Innovative Research's Collagen Type VI Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human COL6. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL6 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL6, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human COL6. You can calculate the concentration of Human COL6 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Collagen Type VI Reactivity: Human Range: 1.56 - 100 ng\/mL Sensitivity: 0.94 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813503643844,"sku":"IHUCOL6KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_926e86a9-1c6b-4d0c-a34f-359705d78ca0.jpg?v=1740173272"},{"product_id":"human-claudin-11-clia-kit","title":"Human Claudin 11 Chemiluminescent Immunoassay Kit","description":"Human Claudin 11 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Claudin 11 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CLDN11 in samples. No significant cross-reactivity or interference between Human CLDN11 and analogues was observed. Innovative Research's Claudin 11 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CLDN11. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CLDN11 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CLDN11, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CLDN11. You can calculate the concentration of Human CLDN11 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Claudin 11 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813506560196,"sku":"IHUCLDN11KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_cfa9c245-755b-4f5f-a528-c4e926819057.jpg?v=1740173298"},{"product_id":"human-n-terminal-pro-brain-natriuretic-peptide-clia-kit","title":"Human N-Terminal Pro-Brain Natriuretic Peptide Chemiluminescent Immunoassay Kit","description":"Human N-Terminal Pro-Brain Natriuretic Peptide Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring N-Terminal Pro-Brain Natriuretic Peptide in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NT-proBNP in samples. No significant cross-reactivity or interference between Human NT-proBNP and analogues was observed. Innovative Research's N-Terminal Pro-Brain Natriuretic Peptide Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NT-proBNP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NT-proBNP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NT-proBNP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NT-proBNP. You can calculate the concentration of Human NT-proBNP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: N-Terminal Pro-Brain Natriuretic Peptide Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813508100292,"sku":"IHUNTPROBNPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_5e943125-2e05-492e-95d7-2a8498207bc8.jpg?v=1740173324"},{"product_id":"human-cadherin-placental-clia-kit","title":"Human Cadherin Placental Chemiluminescent Immunoassay Kit","description":"Human Cadherin, Placental Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cadherin, Placental in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human P-Cadherin in samples. No significant cross-reactivity or interference between Human P-Cadherin and analogues was observed. Innovative Research's Cadherin, Placental Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human P-Cadherin. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human P-Cadherin and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human P-Cadherin, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human P-Cadherin. You can calculate the concentration of Human P-Cadherin in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cadherin, Placental Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813508264132,"sku":"IHUPCADHERINKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_1f4582d3-7fa4-4f45-98c3-4459af299914.jpg?v=1740173328"},{"product_id":"human-tar-dna-binding-protein-43kda-clia-kit","title":"Human Tar DNA Binding Protein 43KDa  Chemiluminescent Immunoassay Kit","description":"Human Tar DNA Binding Protein 43KDa Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Tar DNA Binding Protein 43KDa in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human TDP43 in samples. No significant cross-reactivity or interference between Human TDP43 and analogues was observed. Innovative Research's Tar DNA Binding Protein 43KDa Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human TDP43. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human TDP43 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TDP43, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human TDP43. You can calculate the concentration of Human TDP43 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Tar DNA Binding Protein 43KDa Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813508985028,"sku":"IHUTDP43KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_4a290769-911d-4446-af39-1815ee935866.jpg?v=1740173345"},{"product_id":"human-microtubule-associated-protein-tau-tau-protein-clia-kit","title":"Human Microtubule Associated Protein Tau Tau Protein Chemiluminescent Immunoassay Kit","description":"Human Microtubule Associated Protein Tau\/Tau Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Microtubule Associated Protein Tau\/Tau Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MAPT in samples. No significant cross-reactivity or interference between Human MAPT and analogues was observed. Innovative Research's Microtubule Associated Protein Tau\/Tau Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MAPT. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MAPT and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MAPT, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MAPT. You can calculate the concentration of Human MAPT in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Microtubule Associated Protein Tau\/Tau Protein Reactivity: Human Range: 6.25 - 400 pg\/mL Sensitivity: 3.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813509050564,"sku":"IHUMAPTTAUKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_5ddf38ca-6629-4015-a511-8c350e41906d.jpg?v=1740173348"},{"product_id":"human-synuclein-alpha-clia-kit","title":"Human Synuclein Alpha Chemiluminescent Immunoassay Kit","description":"Human Synuclein Alpha Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Synuclein Alpha in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human SNC? in samples. No significant cross-reactivity or interference between Human SNC? and analogues was observed. Innovative Research's Synuclein Alpha Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human SNC?. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human SNC? and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human SNC?, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human SNC?. You can calculate the concentration of Human SNC? in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Synuclein Alpha Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813509443780,"sku":"IHUSNCAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_b3b827d7-26f0-42cd-936b-3dcb38127ce1.jpg?v=1740173362"},{"product_id":"human-neuron-specific-enolase-clia-kit","title":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit","description":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neuron-Specific Enolase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NSE in samples. No significant cross-reactivity or interference between Human NSE and analogues was observed. Innovative Research's Neuron-Specific Enolase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NSE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NSE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NSE. You can calculate the concentration of Human NSE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neuron-Specific Enolase Reactivity: Human Range: 0.47 - 30 ng\/mL Sensitivity: 0.28 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813512458436,"sku":"IHUNSEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d9adaf8b-5761-49e8-9fa5-e25e66895f52.jpg?v=1740173385"},{"product_id":"human-galectin-7-clia-kit","title":"Human Galectin 7 Chemiluminescent Immunoassay Kit","description":"Human Galectin 7 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Galectin 7 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GAL7 in samples. No significant cross-reactivity or interference between Human GAL7 and analogues was observed. Innovative Research's Galectin 7 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GAL7. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GAL7 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GAL7, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GAL7. You can calculate the concentration of Human GAL7 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Galectin 7 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813512720580,"sku":"IHUGAL7KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aa54ba16-64a1-40fe-a1fc-143bc2da405e.jpg?v=1740173396"},{"product_id":"human-vimentin-clia-kit","title":"Human Vimentin Chemiluminescent Immunoassay Kit","description":"Human Vimentin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Vimentin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human VIM in samples. No significant cross-reactivity or interference between Human VIM and analogues was observed. Innovative Research's Vimentin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human VIM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human VIM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human VIM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human VIM. You can calculate the concentration of Human VIM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Vimentin Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813513244868,"sku":"IHUVIMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_10427356-96f1-42e3-b819-9981d44eee10.jpg?v=1740173411"},{"product_id":"human-estrogen-receptor-alpha-clia-kit","title":"Human Estrogen Receptor Alpha Chemiluminescent Immunoassay Kit","description":"Human Estrogen Receptor Alpha Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Estrogen Receptor Alpha in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ER? in samples. No significant cross-reactivity or interference between Human ER? and analogues was observed. Innovative Research's Estrogen Receptor Alpha Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ER?. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ER? and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ER?, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ER?. You can calculate the concentration of Human ER? in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Estrogen Receptor Alpha Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813513867460,"sku":"IHUERAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d243653a-88b1-4e63-aebb-16ee3873c2a4.jpg?v=1740173434"},{"product_id":"human-fatty-acid-binding-protein-7-brain-clia-kit","title":"Human Fatty Acid Binding Protein 7 Brain Chemiluminescent Immunoassay Kit","description":"Human Fatty Acid Binding Protein 7, Brain Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Fatty Acid Binding Protein 7, Brain in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human FABP7 in samples. No significant cross-reactivity or interference between Human FABP7 and analogues was observed. Innovative Research's Fatty Acid Binding Protein 7, Brain Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human FABP7. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FABP7 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FABP7, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human FABP7. You can calculate the concentration of Human FABP7 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Fatty Acid Binding Protein 7, Brain Reactivity: Human Range: 0.16 - 10 ng\/mL Sensitivity: 0.09 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813514096836,"sku":"IHUFABP7KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_cdfc4ece-8d6d-47c2-b502-1983e9814a7e.jpg?v=1740173440"},{"product_id":"human-nerve-growth-factor-clia-kit","title":"Human Nerve Growth Factor Chemiluminescent Immunoassay Kit","description":"Human Nerve Growth Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Nerve Growth Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NGF in samples. No significant cross-reactivity or interference between Human NGF and analogues was observed. Innovative Research's Nerve Growth Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NGF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NGF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NGF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NGF. You can calculate the concentration of Human NGF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Nerve Growth Factor Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813514424516,"sku":"IHUNGFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_40a71ed2-1809-498a-a3d4-ce3510267183.jpg?v=1740173454"},{"product_id":"human-amyloid-precursor-protein-clia-kit","title":"Human Amyloid Precursor Protein Chemiluminescent Immunoassay Kit","description":"Human Amyloid Precursor Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Amyloid Precursor Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human APP in samples. No significant cross-reactivity or interference between Human APP and analogues was observed. Innovative Research's Amyloid Precursor Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human APP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human APP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human APP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human APP. You can calculate the concentration of Human APP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Amyloid Precursor Protein Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813515112644,"sku":"IHUAPPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_6f9c25fb-32e7-4f1f-8027-ea5aa7f5680e.jpg?v=1740173461"},{"product_id":"human-dopamine-b-hydroxylase-clia-kit","title":"Human Dopamine-B-Hydroxylase Chemiluminescent Immunoassay Kit","description":"Human Dopamine-B-Hydroxylase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Dopamine-B-Hydroxylase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human DBH in samples. No significant cross-reactivity or interference between Human DBH and analogues was observed. Innovative Research's Dopamine-B-Hydroxylase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human DBH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human DBH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human DBH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human DBH. You can calculate the concentration of Human DBH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Dopamine-B-Hydroxylase Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862972182724,"sku":"IHUDBHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_05820ed7-c1d9-41ec-a5f7-d181fee20831.jpg?v=1740173516"},{"product_id":"human-dopamine-decarboxylase-clia-kit","title":"Human Dopamine Decarboxylase Chemiluminescent Immunoassay Kit","description":"Human Dopamine Decarboxylase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Dopamine Decarboxylase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human DDC in samples. No significant cross-reactivity or interference between Human DDC and analogues was observed. Innovative Research's Dopamine Decarboxylase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human DDC. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human DDC and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human DDC, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human DDC. You can calculate the concentration of Human DDC in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Dopamine Decarboxylase Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862972477636,"sku":"IHUDDCKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9d34f3a3-c458-4188-901c-a21017b77bf5.jpg?v=1740173518"},{"product_id":"human-dopamine-transporter-clia-kit","title":"Human Dopamine Transporter Chemiluminescent Immunoassay Kit","description":"Human Dopamine Transporter Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Dopamine Transporter in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human DAT in samples. No significant cross-reactivity or interference between Human DAT and analogues was observed. Innovative Research's Dopamine Transporter Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human DAT. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human DAT and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human DAT, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human DAT. You can calculate the concentration of Human DAT in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Dopamine Transporter Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862972707012,"sku":"IHUDATKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_59ed8eec-7644-490c-84a2-e10347fd14de.jpg?v=1740173519"},{"product_id":"human-ubiquitin-protein-ligase-e3a-clia-kit","title":"Human Ubiquitin Protein Ligase E3A Chemiluminescent Immunoassay Kit","description":"Human Ubiquitin Protein Ligase E3A Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Ubiquitin Protein Ligase E3A in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human UBE3A in samples. No significant cross-reactivity or interference between Human UBE3A and analogues was observed. Innovative Research's Ubiquitin Protein Ligase E3A Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human UBE3A. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human UBE3A and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human UBE3A, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human UBE3A. You can calculate the concentration of Human UBE3A in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Ubiquitin Protein Ligase E3A Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862974050500,"sku":"IHUUBE3AKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_714b122f-80e9-4ca6-a1d5-761c1456f412.jpg?v=1740173534"},{"product_id":"human-semaphorin-3a-clia-kit","title":"Human Semaphorin 3A Chemiluminescent Immunoassay Kit","description":"Human Semaphorin 3A Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Semaphorin 3A in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human SEMA3A in samples. No significant cross-reactivity or interference between Human SEMA3A and analogues was observed. Innovative Research's Semaphorin 3A Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human SEMA3A. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human SEMA3A and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human SEMA3A, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human SEMA3A. You can calculate the concentration of Human SEMA3A in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Semaphorin 3A Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862975459524,"sku":"IHUSEMA3AKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_3365e587-e201-49dc-b495-daba65e6d833.jpg?v=1740173547"},{"product_id":"human-glutathione-s-transferases-pi-clia-kit","title":"Human Glutathione S Transferases Pi Chemiluminescent Immunoassay Kit","description":"Human Glutathione S Transferases Pi Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glutathione S Transferases Pi in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GSTpi in samples. No significant cross-reactivity or interference between Human GSTpi and analogues was observed. Innovative Research's Glutathione S Transferases Pi Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GSTpi. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GSTpi and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GSTpi, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GSTpi. You can calculate the concentration of Human GSTpi in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glutathione S Transferases Pi Reactivity: Human Range: 0.47 - 30 ng\/mL Sensitivity: 0.28 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40862980374724,"sku":"IHUGSTPIKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_64585863-ffaf-4a3b-9e3d-60df8fc4e3c3.jpg?v=1740173588"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/collections\/Enzymes-Proteins_a7b138eb-0985-4b21-b52a-dd969e56e255.png?v=1646686516","url":"https:\/\/www.innov-research.com\/collections\/neuroscience.oembed?page=45","provider":"Innovative Research","version":"1.0","type":"link"}