{"title":"Metabolism","description":"\u003cp\u003eStudy the complex biochemical processes involved in energy production and utilization with our metabolism products. Our offerings include metabolic pathway analysis kits, enzyme inhibitors, and stable isotope tracers, enabling you to investigate metabolic disorders, drug metabolism, and more.\u003c\/p\u003e","products":[{"product_id":"lepr-recombinant-protein-c-fc-tag-lyophilized","title":"LEPR Recombinant Protein C-Fc Tag Lyophilized","description":"\u003cp\u003eLEPR Recombinant Protein C-Fc Tag Lyophilized from Innovative Research has been recombinantly produced in Human Cells. The protein formulation is lyophilized from a 0.2 ?m filtered solution of PBS, pH 7.4. with a purity of \u0026gt; 95 % as determined by reducing SDS-PAGE.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e LEPR\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePurity:\u003c\/b\u003e \u0026gt; 95 % as determined by reducing SDS-PAGE. \u0026lt; 1.0 EU per µg as determined by the LAL method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSource:\u003c\/b\u003e Human Cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Lyophilized proteins are stable for up to 12 months when stored at -20 to -80C. Reconstituted protein solution can be stored at 4-8C for 2-7 days. Aliquots of reconstituted samples are stable at \u0026lt; -20C for 3 months.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis product is provided as lyophilized powder and is shipped with ice packs.\u003c\/p\u003e\u003cp\u003eFor research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"10ug","offer_id":42109263085764,"sku":"IHULEPRRCFCLY10UG","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/66211b8b-ccf5-459c-bd40-6ec9ff2c4d10_a2c02ce7-4767-40e6-a97a-0d5a91c9ea56.jpg?v=1740020144"},{"product_id":"human-adiponectin-clia-kit","title":"Human Adiponectin Chemiluminescent Immunoassay Kit","description":"Human Adiponectin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adiponectin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADP\/Acrp30 in samples. No significant cross-reactivity or interference between Human ADP\/Acrp30 and analogues was observed. Innovative Research's Adiponectin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADP\/Acrp30. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADP\/Acrp30 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADP\/Acrp30, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADP\/Acrp30. You can calculate the concentration of Human ADP\/Acrp30 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adiponectin Reactivity: Human Range: 0.78 - 50 ng\/mL Sensitivity: 0.47 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813469139140,"sku":"IHUADPNKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_07ea66dd-aa1a-451b-b76b-63cfebced492.jpg?v=1740172756"},{"product_id":"human-caspase-1-clia-kit","title":"Human Caspase 1 Chemiluminescent Immunoassay Kit","description":"Human Caspase 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Caspase 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CASP1 in samples. No significant cross-reactivity or interference between Human CASP1 and analogues was observed. Innovative Research's Caspase 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CASP1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CASP1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CASP1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CASP1. You can calculate the concentration of Human CASP1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Caspase 1 Reactivity: Human Range: 6.25 - 400 pg\/mL Sensitivity: 3.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813469565124,"sku":"IHUCASP1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_1fec772e-6ed7-4ff7-8b8d-1a026509b95f.jpg?v=1740172771"},{"product_id":"human-monocyte-chemotactic-protein-1-clia-kit","title":"Human Monocyte Chemotactic Protein 1 Chemiluminescent Immunoassay Kit","description":"Human Monocyte Chemotactic Protein 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Monocyte Chemotactic Protein 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MCP-1 in samples. No significant cross-reactivity or interference between Human MCP-1 and analogues was observed. Innovative Research's Monocyte Chemotactic Protein 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MCP-1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MCP-1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MCP-1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MCP-1. You can calculate the concentration of Human MCP-1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Monocyte Chemotactic Protein 1 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813470286020,"sku":"IHUMCP1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_26249eb4-f48d-40a1-be2f-cd3056b0ce51.jpg?v=1740172777"},{"product_id":"human-c-reactive-protein-clia-kit","title":"Human C-Reactive Protein Chemiluminescent Immunoassay Kit","description":"Human C-Reactive Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring C-Reactive Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CRP in samples. No significant cross-reactivity or interference between Human CRP and analogues was observed. Innovative Research's C-Reactive Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CRP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CRP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CRP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CRP. You can calculate the concentration of Human CRP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: C-Reactive Protein Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813471203524,"sku":"IHUCRPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_443f3749-17e3-4978-a41d-29e2159a848f.jpg?v=1740172802"},{"product_id":"human-cytochrome-c-clia-kit","title":"Human Cytochrome C Chemiluminescent Immunoassay Kit","description":"Human Cytochrome C Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cytochrome C in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human Cyt-C in samples. No significant cross-reactivity or interference between Human Cyt-C and analogues was observed. Innovative Research's Cytochrome C Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human Cyt-C. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human Cyt-C and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human Cyt-C, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human Cyt-C. You can calculate the concentration of Human Cyt-C in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cytochrome C Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813473759428,"sku":"IHUCYCSKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_7f496210-a82d-4817-ba36-efb108f333f3.jpg?v=1740172818"},{"product_id":"human-endothelin-1-clia-kit","title":"Human Endothelin 1 Chemiluminescent Immunoassay Kit","description":"Human Endothelin 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Endothelin 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ET-1 in samples. No significant cross-reactivity or interference between Human ET-1 and analogues was observed. Innovative Research's Endothelin 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ET-1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ET-1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ET-1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ET-1. You can calculate the concentration of Human ET-1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Endothelin 1 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813474480324,"sku":"IHUEDN1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aa96400d-8671-4a50-b4c5-6831ec40d9e0.jpg?v=1740172829"},{"product_id":"human-erythropoietin-clia-kit","title":"Human Erythropoietin Chemiluminescent Immunoassay Kit","description":"Human Erythropoietin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Erythropoietin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human EPO in samples. No significant cross-reactivity or interference between Human EPO and analogues was observed. Innovative Research's Erythropoietin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human EPO. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human EPO and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human EPO, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human EPO. You can calculate the concentration of Human EPO in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Erythropoietin Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813474545860,"sku":"IHUEPOKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_e2d1eed6-add9-4106-93f5-5a975b6a479f.jpg?v=1740172831"},{"product_id":"human-hepcidin-clia-kit","title":"Human Hepcidin Chemiluminescent Immunoassay Kit","description":"Human Hepcidin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Hepcidin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human Hepc in samples. No significant cross-reactivity or interference between Human Hepc and analogues was observed. Innovative Research's Hepcidin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human Hepc. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human Hepc and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human Hepc, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human Hepc. You can calculate the concentration of Human Hepc in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Hepcidin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813475070148,"sku":"IHUHAMPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_28674cfd-1aab-4ecb-bd6d-217402a38cfd.jpg?v=1740172844"},{"product_id":"human-interleukin-1-alpha-clia-kit","title":"Human Interleukin 1 Alpha Chemiluminescent Immunoassay Kit","description":"Human Interleukin 1 Alpha Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Interleukin 1 Alpha in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IL-1? in samples. No significant cross-reactivity or interference between Human IL-1? and analogues was observed. Innovative Research's Interleukin 1 Alpha Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IL-1?. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-1? and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-1?, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IL-1?. You can calculate the concentration of Human IL-1? in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Interleukin 1 Alpha Reactivity: Human Range: 3.91 - 250 pg\/mL Sensitivity: 2.34 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813475397828,"sku":"IHUIL1AKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_e15f4606-3bb8-4e5c-b55d-9348975e99c3.jpg?v=1740172857"},{"product_id":"human-neutrophil-gelatinase-associated-lipocalin-clia-kit","title":"Human Neutrophil Gelatinase Associated Lipocalin Chemiluminescent Immunoassay Kit","description":"Human Neutrophil Gelatinase Associated Lipocalin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neutrophil Gelatinase Associated Lipocalin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NGAL in samples. No significant cross-reactivity or interference between Human NGAL and analogues was observed. Innovative Research's Neutrophil Gelatinase Associated Lipocalin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NGAL. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NGAL and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NGAL, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NGAL. You can calculate the concentration of Human NGAL in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neutrophil Gelatinase Associated Lipocalin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813475954884,"sku":"IHUNGALKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d3ca8090-235a-40d6-974d-289d404514fe.jpg?v=1740172865"},{"product_id":"human-interleukin-6-clia-kit","title":"Human Interleukin 6 Chemiluminescent Immunoassay Kit","description":"Human Interleukin 6 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Interleukin 6 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IL-6 in samples. No significant cross-reactivity or interference between Human IL-6 and analogues was observed. Innovative Research's Interleukin 6 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IL-6. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-6 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-6, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IL-6. You can calculate the concentration of Human IL-6 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Interleukin 6 Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813476806852,"sku":"IHUIL6KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9d0de6ed-45ae-4d71-a816-8ce171421444.jpg?v=1740172872"},{"product_id":"human-tumor-necrosis-factor-alpha-clia-kit","title":"Human Tumor Necrosis Factor Alpha Chemiluminescent Immunoassay Kit","description":"Human Tumor Necrosis Factor Alpha Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Tumor Necrosis Factor Alpha in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human TNF-? in samples. No significant cross-reactivity or interference between Human TNF-? and analogues was observed. Innovative Research's Tumor Necrosis Factor Alpha Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human TNF-?. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human TNF-? and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TNF-?, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human TNF-?. You can calculate the concentration of Human TNF-? in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Tumor Necrosis Factor Alpha Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813477560516,"sku":"IHUTNFAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_155ab6ab-0e59-4653-872a-40ee85dceeba.jpg?v=1740172882"},{"product_id":"human-leptin-clia-kit","title":"Human Leptin Chemiluminescent Immunoassay Kit","description":"Human Leptin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Leptin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human LEP in samples. No significant cross-reactivity or interference between Human LEP and analogues was observed. Innovative Research's Leptin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human LEP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human LEP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human LEP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human LEP. You can calculate the concentration of Human LEP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Leptin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813477724356,"sku":"IHULEPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_11a6bb8d-808b-4cdb-9ff1-52d922654284.jpg?v=1740172886"},{"product_id":"human-oxidized-low-density-lipoprotein-clia-kit","title":"Human Oxidized Low Density Lipoprotein Chemiluminescent Immunoassay Kit","description":"Human Oxidized Low Density Lipoprotein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Oxidized Low Density Lipoprotein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human OxLDL in samples. No significant cross-reactivity or interference between Human OxLDL and analogues was observed. Innovative Research's Oxidized Low Density Lipoprotein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human OxLDL. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human OxLDL and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human OxLDL, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human OxLDL. You can calculate the concentration of Human OxLDL in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Oxidized Low Density Lipoprotein Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813477953732,"sku":"IHUOXLDLKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9f7578cf-49b3-44d1-a7e5-172f07930ea0.jpg?v=1740172895"},{"product_id":"human-myoglobin-clia-kit","title":"Human Myoglobin Chemiluminescent Immunoassay Kit","description":"Human Myoglobin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Myoglobin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MYO in samples. No significant cross-reactivity or interference between Human MYO and analogues was observed. Innovative Research's Myoglobin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MYO. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MYO and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MYO, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MYO. You can calculate the concentration of Human MYO in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Myoglobin Reactivity: Human Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813478314180,"sku":"IHUMBKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_471d9bc7-8149-4ca8-bcab-b1a12c015fac.jpg?v=1740172906"},{"product_id":"human-interleukin-1-beta-clia-kit","title":"Human Interleukin 1 Beta Chemiluminescent Immunoassay Kit","description":"Human Interleukin 1 Beta Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Interleukin 1 Beta in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IL-1? in samples. No significant cross-reactivity or interference between Human IL-1? and analogues was observed. Innovative Research's Interleukin 1 Beta Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IL-1?. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-1? and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-1?, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IL-1?. You can calculate the concentration of Human IL-1? in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Interleukin 1 Beta Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479166148,"sku":"IHUIL1BKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_3aaf751a-7738-4830-8a96-40287f3c4ec0.jpg?v=1740172910"},{"product_id":"human-ferritin-clia-kit","title":"Human Ferritin Chemiluminescent Immunoassay Kit","description":"Human Ferritin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Ferritin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human FE in samples. No significant cross-reactivity or interference between Human FE and analogues was observed. Innovative Research's Ferritin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human FE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human FE. You can calculate the concentration of Human FE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Ferritin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479755972,"sku":"IHUFTKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_57949cee-c187-4032-b94c-8c93f48522b1.jpg?v=1740172928"},{"product_id":"human-chorionic-gonadotropin-clia-kit","title":"Human Chorionic Gonadotropin Chemiluminescent Immunoassay Kit","description":"Human Chorionic Gonadotropin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Chorionic Gonadotropin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CG in samples. No significant cross-reactivity or interference between Human CG and analogues was observed. Innovative Research's Chorionic Gonadotropin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CG. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CG and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CG, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CG. You can calculate the concentration of Human CG in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Chorionic Gonadotropin Reactivity: Human Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813479919812,"sku":"IHUCGKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d9bce686-2302-440c-a27f-1ff6cc3cb965.jpg?v=1740172934"},{"product_id":"human-complement-component-5a-clia-kit","title":"Human Complement Component 5a Chemiluminescent Immunoassay Kit","description":"Human Complement Component 5a Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Complement Component 5a in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human C5a in samples. No significant cross-reactivity or interference between Human C5a and analogues was observed. Innovative Research's Complement Component 5a Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human C5a. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human C5a and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human C5a, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human C5a. You can calculate the concentration of Human C5a in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Complement Component 5a Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813480640708,"sku":"IHUC5AKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d930b791-83f2-4c46-9ba0-ad4323a12a5d.jpg?v=1740172949"},{"product_id":"human-interleukin-18-clia-kit","title":"Human Interleukin 18 Chemiluminescent Immunoassay Kit","description":"Human Interleukin 18 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Interleukin 18 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IL-18 in samples. No significant cross-reactivity or interference between Human IL-18 and analogues was observed. Innovative Research's Interleukin 18 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IL-18. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-18 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-18, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IL-18. You can calculate the concentration of Human IL-18 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Interleukin 18 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813482082500,"sku":"IHUIL18KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_7cf97fa5-77a5-4d82-87d9-e460cae527b8.jpg?v=1740172967"},{"product_id":"human-adiponectin-receptor-2-clia-kit","title":"Human Adiponectin Receptor 2 Chemiluminescent Immunoassay Kit","description":"Human Adiponectin Receptor 2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adiponectin Receptor 2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADIPOR2 in samples. No significant cross-reactivity or interference between Human ADIPOR2 and analogues was observed. Innovative Research's Adiponectin Receptor 2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADIPOR2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADIPOR2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADIPOR2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADIPOR2. You can calculate the concentration of Human ADIPOR2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adiponectin Receptor 2 Reactivity: Human Range: 0.16 - 10 ng\/mL Sensitivity: 0.09 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485260996,"sku":"IHUADIPOR2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_4d677d03-474b-408b-a709-f4e31bc07b5d.jpg?v=1740172980"},{"product_id":"human-adrenomedullin-clia-kit","title":"Human Adrenomedullin Chemiluminescent Immunoassay Kit","description":"Human Adrenomedullin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adrenomedullin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADM in samples. No significant cross-reactivity or interference between Human ADM and analogues was observed. Innovative Research's Adrenomedullin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADM. You can calculate the concentration of Human ADM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adrenomedullin Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485293764,"sku":"IHUADMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_9af33ab0-3060-4cf4-850e-710b93fb7e5f.jpg?v=1740172981"},{"product_id":"human-adipose-differentiation-related-protein-clia-kit","title":"Human Adipose Differentiation Related Protein Chemiluminescent Immunoassay Kit","description":"Human Adipose Differentiation Related Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Adipose Differentiation Related Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ADRP in samples. No significant cross-reactivity or interference between Human ADRP and analogues was observed. Innovative Research's Adipose Differentiation Related Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ADRP. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ADRP and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ADRP, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ADRP. You can calculate the concentration of Human ADRP in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Adipose Differentiation Related Protein Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485359300,"sku":"IHUADRPKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_466bbcd1-fee3-480a-850d-ddd6a6c06266.jpg?v=1740172983"},{"product_id":"human-angiotensinogen-clia-kit","title":"Human Angiotensinogen Chemiluminescent Immunoassay Kit","description":"Human Angiotensinogen Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Angiotensinogen in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AGT in samples. No significant cross-reactivity or interference between Human AGT and analogues was observed. Innovative Research's Angiotensinogen Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AGT. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGT and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGT, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AGT. You can calculate the concentration of Human AGT in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Angiotensinogen Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486080196,"sku":"IHUAGTKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_10c76354-319a-465e-83f9-413e1bcb9f21.jpg?v=1740172999"},{"product_id":"human-allograft-inflammatory-factor-1-clia-kit","title":"Human Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay Kit","description":"Human Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Allograft Inflammatory Factor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AIF1 in samples. No significant cross-reactivity or interference between Human AIF1 and analogues was observed. Innovative Research's Allograft Inflammatory Factor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AIF1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AIF1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AIF1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AIF1. You can calculate the concentration of Human AIF1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Allograft Inflammatory Factor 1 Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486112964,"sku":"IHUAIF1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_5b0aaa95-7615-4b05-863b-6425989a418c.jpg?v=1740173000"},{"product_id":"human-aldolase-a-fructose-bisphosphate-clia-kit","title":"Human Aldolase A Fructose Bisphosphate Chemiluminescent Immunoassay Kit","description":"Human Aldolase A, Fructose Bisphosphate Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Aldolase A, Fructose Bisphosphate in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ALDOA in samples. No significant cross-reactivity or interference between Human ALDOA and analogues was observed. Innovative Research's Aldolase A, Fructose Bisphosphate Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ALDOA. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ALDOA and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ALDOA, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ALDOA. You can calculate the concentration of Human ALDOA in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Aldolase A, Fructose Bisphosphate Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486178500,"sku":"IHUALDOAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_4a14ffe2-2d61-4280-bb52-ade8bcbfd6ed.jpg?v=1740173002"},{"product_id":"human-phosphorylated-adenosine-monophosphate-activated-protein-kinase-clia-kit","title":"Human Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay Kit","description":"Human Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Phosphorylated Adenosine Monophosphate Activated Protein Kinase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AMPK in samples. No significant cross-reactivity or interference between Human AMPK and analogues was observed. Innovative Research's Phosphorylated Adenosine Monophosphate Activated Protein Kinase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AMPK. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AMPK and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AMPK, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AMPK. You can calculate the concentration of Human AMPK in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Phosphorylated Adenosine Monophosphate Activated Protein Kinase Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486375108,"sku":"IHUAMPKKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aebdfd56-d363-41c3-8974-7c13dfcdff2c.jpg?v=1740173009"},{"product_id":"human-amylase-alpha-1-salivary-clia-kit","title":"Human Amylase Alpha 1 Salivary Chemiluminescent Immunoassay Kit","description":"Human Amylase Alpha 1, Salivary Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Amylase Alpha 1, Salivary in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AMY1 in samples. No significant cross-reactivity or interference between Human AMY1 and analogues was observed. Innovative Research's Amylase Alpha 1, Salivary Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AMY1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AMY1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AMY1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AMY1. You can calculate the concentration of Human AMY1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Amylase Alpha 1, Salivary Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486440644,"sku":"IHUAMY1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_91d7fa4e-c896-4d3b-afaf-fb36ee309e6f.jpg?v=1740173011"},{"product_id":"human-angiopoietin-4-clia-kit","title":"Human Angiopoietin 4 Chemiluminescent Immunoassay Kit","description":"Human Angiopoietin 4 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Angiopoietin 4 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ANGPT4 in samples. No significant cross-reactivity or interference between Human ANGPT4 and analogues was observed. Innovative Research's Angiopoietin 4 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ANGPT4. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ANGPT4 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ANGPT4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ANGPT4. You can calculate the concentration of Human ANGPT4 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Angiopoietin 4 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486571716,"sku":"IHUANGPT4KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_a7920afe-226a-45d3-acf6-076802e284d9.jpg?v=1740173013"},{"product_id":"human-angiopoietin-like-protein-4-clia-kit","title":"Human Angiopoietin Like Protein 4 Chemiluminescent Immunoassay Kit","description":"Human Angiopoietin Like Protein 4 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Angiopoietin Like Protein 4 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ANGPTL4 in samples. No significant cross-reactivity or interference between Human ANGPTL4 and analogues was observed. Innovative Research's Angiopoietin Like Protein 4 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ANGPTL4. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ANGPTL4 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ANGPTL4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ANGPTL4. You can calculate the concentration of Human ANGPTL4 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Angiopoietin Like Protein 4 Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486702788,"sku":"IHUANGPTL4KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_ef6f6864-f04c-49d7-9674-4bccc9ac8188.jpg?v=1740173018"},{"product_id":"human-angiopoietin-like-protein-6-clia-kit","title":"Human Angiopoietin Like Protein 6 Chemiluminescent Immunoassay Kit","description":"Human Angiopoietin Like Protein 6 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Angiopoietin Like Protein 6 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ANGPTL6 in samples. No significant cross-reactivity or interference between Human ANGPTL6 and analogues was observed. Innovative Research's Angiopoietin Like Protein 6 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ANGPTL6. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ANGPTL6 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ANGPTL6, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ANGPTL6. You can calculate the concentration of Human ANGPTL6 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Angiopoietin Like Protein 6 Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486735556,"sku":"IHUANGPTL6KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_e35c9032-9e27-4e84-94fc-420bf3889c7f.jpg?v=1740173020"},{"product_id":"human-aconitase-1-clia-kit","title":"Human Aconitase 1 Chemiluminescent Immunoassay Kit","description":"Human Aconitase 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Aconitase 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ACO1 in samples. No significant cross-reactivity or interference between Human ACO1 and analogues was observed. Innovative Research's Aconitase 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ACO1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ACO1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ACO1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ACO1. You can calculate the concentration of Human ACO1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Aconitase 1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813487096004,"sku":"IHUACO1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_000dae56-a1ed-43bc-aed2-bc6f753f176a.jpg?v=1740173030"},{"product_id":"human-gastric-intrinsic-factor-clia-kit","title":"Human Gastric Intrinsic Factor Chemiluminescent Immunoassay Kit","description":"Human Gastric Intrinsic Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Gastric Intrinsic Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GIF in samples. No significant cross-reactivity or interference between Human GIF and analogues was observed. Innovative Research's Gastric Intrinsic Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GIF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GIF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GIF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GIF. You can calculate the concentration of Human GIF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Gastric Intrinsic Factor Reactivity: Human Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813488505028,"sku":"IHUGIFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d07e0ba4-c249-4fc1-8a9e-2b1f54e00023.jpg?v=1740173060"},{"product_id":"human-insulin-degrading-enzyme-clia-kit","title":"Human Insulin Degrading Enzyme Chemiluminescent Immunoassay Kit","description":"Human Insulin Degrading Enzyme Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin Degrading Enzyme in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IDE in samples. No significant cross-reactivity or interference between Human IDE and analogues was observed. Innovative Research's Insulin Degrading Enzyme Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IDE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IDE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IDE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IDE. You can calculate the concentration of Human IDE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin Degrading Enzyme Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813492895940,"sku":"IHUIDEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_42277037-d791-4593-8d93-58934672e9c0.jpg?v=1740173082"},{"product_id":"human-insulin-receptor-clia-kit","title":"Human Insulin Receptor Chemiluminescent Immunoassay Kit","description":"Human Insulin Receptor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin Receptor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human INSR in samples. No significant cross-reactivity or interference between Human INSR and analogues was observed. Innovative Research's Insulin Receptor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human INSR. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human INSR and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human INSR, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human INSR. You can calculate the concentration of Human INSR in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin Receptor Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813495353540,"sku":"IHUINSRKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_aea453ed-d006-459a-8ae3-a06850504680.jpg?v=1740173100"},{"product_id":"human-apolipoprotein-a2-clia-kit","title":"Human Apolipoprotein A2 Chemiluminescent Immunoassay Kit","description":"Human Apolipoprotein A2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein A2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ApoA2 in samples. No significant cross-reactivity or interference between Human ApoA2 and analogues was observed. Innovative Research's Apolipoprotein A2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ApoA2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoA2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoA2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoA2. You can calculate the concentration of Human ApoA2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein A2 Reactivity: Human Range: 12.5 - 800 ng\/mL Sensitivity: 7.5 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813495582916,"sku":"IHUAPOA2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_016490eb-a0ac-4449-b4ad-6e3d312de340.jpg?v=1740173102"},{"product_id":"human-apolipoprotein-b-clia-kit","title":"Human Apolipoprotein B Chemiluminescent Immunoassay Kit","description":"Human Apolipoprotein B Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein B in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ApoB in samples. No significant cross-reactivity or interference between Human ApoB and analogues was observed. Innovative Research's Apolipoprotein B Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ApoB. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoB and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoB, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoB. You can calculate the concentration of Human ApoB in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein B Reactivity: Human Range: 15.63 - 1000 ng\/mL Sensitivity: 9.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813495681220,"sku":"IHUAPOBKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_357479cb-84a9-447b-b548-9756b2987168.jpg?v=1740173105"},{"product_id":"human-apolipoprotein-c3-clia-kit","title":"Human Apolipoprotein C3 Chemiluminescent Immunoassay Kit","description":"Human Apolipoprotein C3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein C3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ApoC3 in samples. No significant cross-reactivity or interference between Human ApoC3 and analogues was observed. Innovative Research's Apolipoprotein C3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ApoC3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoC3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoC3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoC3. You can calculate the concentration of Human ApoC3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein C3 Reactivity: Human Range: 78.13 - 5000 pg\/mL Sensitivity: 46.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813495779524,"sku":"IHUAPOC3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_e50e06a6-9576-4dae-bf73-8134fe6a39f8.jpg?v=1740173109"},{"product_id":"human-apolipoprotein-h-clia-kit","title":"Human Apolipoprotein H Chemiluminescent Immunoassay Kit","description":"Human Apolipoprotein H Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein H in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ApoH in samples. No significant cross-reactivity or interference between Human ApoH and analogues was observed. Innovative Research's Apolipoprotein H Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ApoH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoH. You can calculate the concentration of Human ApoH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein H Reactivity: Human Range: 78.13 - 5000 pg\/mL Sensitivity: 46.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496074436,"sku":"IHUAPOHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_676cdf86-44c8-4068-9da7-e87bfd234c53.jpg?v=1740173116"},{"product_id":"human-apolipoprotein-a5-clia-kit","title":"Human Apolipoprotein A5 Chemiluminescent Immunoassay Kit","description":"Human Apolipoprotein A5 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein A5 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ApoA5 in samples. No significant cross-reactivity or interference between Human ApoA5 and analogues was observed. Innovative Research's Apolipoprotein A5 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ApoA5. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoA5 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoA5, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoA5. You can calculate the concentration of Human ApoA5 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein A5 Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496139972,"sku":"IHUAPOA5KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c1f82747-f686-442a-9199-325d070eb002.jpg?v=1740173119"},{"product_id":"human-apoptosis-inducing-factor-clia-kit","title":"Human Apoptosis Inducing Factor Chemiluminescent Immunoassay Kit","description":"Human Apoptosis Inducing Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apoptosis Inducing Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AIF in samples. No significant cross-reactivity or interference between Human AIF and analogues was observed. Innovative Research's Apoptosis Inducing Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AIF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AIF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AIF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AIF. You can calculate the concentration of Human AIF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apoptosis Inducing Factor Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496172740,"sku":"IHUAIFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d4560540-c4bc-4648-b670-a3d2bdacfa01.jpg?v=1740173120"},{"product_id":"human-atp-binding-cassette-transporter-g1-clia-kit","title":"Human ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay Kit","description":"Human ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring ATP Binding Cassette Transporter G1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ABCG1 in samples. No significant cross-reactivity or interference between Human ABCG1 and analogues was observed. Innovative Research's ATP Binding Cassette Transporter G1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ABCG1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ABCG1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ABCG1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ABCG1. You can calculate the concentration of Human ABCG1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: ATP Binding Cassette Transporter G1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497057476,"sku":"IHUABCG1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_ae20226d-3ebf-4f4e-bc71-007780d29685.jpg?v=1740173145"},{"product_id":"human-atp-binding-cassette-transporter-a1-clia-kit","title":"Human ATP-binding cassette transporter A1 Chemiluminescent Immunoassay Kit","description":"Human ATP-binding cassette transporter A1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring ATP-binding cassette transporter A1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ABCA1 in samples. No significant cross-reactivity or interference between Human ABCA1 and analogues was observed. Innovative Research's ATP-binding cassette transporter A1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ABCA1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ABCA1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ABCA1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ABCA1. You can calculate the concentration of Human ABCA1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: ATP-binding cassette transporter A1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497123012,"sku":"IHUABCA1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_71201e7b-9c87-4ef9-8361-0f7184aa6e22.jpg?v=1740173146"},{"product_id":"human-bcl-2-like-protein-1-bcl2-associated-x-protein-clia-kit","title":"Human Bcl-2 Like Protein 1 Bcl2 Associated X Protein Chemiluminescent Immunoassay Kit","description":"Human Bcl-2 Like Protein 1\/Bcl2 Associated X Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bcl-2 Like Protein 1\/Bcl2 Associated X Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human BCL2L1\/BCL-X in samples. No significant cross-reactivity or interference between Human BCL2L1\/BCL-X and analogues was observed. Innovative Research's Bcl-2 Like Protein 1\/Bcl2 Associated X Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human BCL2L1\/BCL-X. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human BCL2L1\/BCL-X and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human BCL2L1\/BCL-X, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human BCL2L1\/BCL-X. You can calculate the concentration of Human BCL2L1\/BCL-X in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bcl-2 Like Protein 1\/Bcl2 Associated X Protein Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497483460,"sku":"IHUBCL2L1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_bbb26252-fec4-4596-965d-8523017afd89.jpg?v=1740173156"},{"product_id":"human-lactate-dehydrogenase-a-clia-kit","title":"Human Lactate Dehydrogenase A Chemiluminescent Immunoassay Kit","description":"Human Lactate Dehydrogenase A Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Lactate Dehydrogenase A in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human LDHA in samples. No significant cross-reactivity or interference between Human LDHA and analogues was observed. Innovative Research's Lactate Dehydrogenase A Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human LDHA. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human LDHA and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human LDHA, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human LDHA. You can calculate the concentration of Human LDHA in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Lactate Dehydrogenase A Reactivity: Human Range: 0.16 - 10 ng\/mL Sensitivity: 0.09 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497680068,"sku":"IHULDHAKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c7a4de85-691f-4d2b-9fa3-b9bb0d6285c1.jpg?v=1740173161"},{"product_id":"human-bcl-2-associated-x-protein-clia-kit","title":"Human Bcl-2 Associated X Protein Chemiluminescent Immunoassay Kit","description":"Human Bcl-2 Associated X Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bcl-2 Associated X Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human Bax in samples. No significant cross-reactivity or interference between Human Bax and analogues was observed. Innovative Research's Bcl-2 Associated X Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human Bax. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human Bax and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human Bax, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human Bax. You can calculate the concentration of Human Bax in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bcl-2 Associated X Protein Reactivity: Human Range: 0.16 - 10 ng\/mL Sensitivity: 0.09 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813497745604,"sku":"IHUBAXKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_65956e39-735a-47bb-8ccb-e4b2b0d4592a.jpg?v=1740173165"},{"product_id":"human-metallothionein-3-clia-kit","title":"Human Metallothionein 3 Chemiluminescent Immunoassay Kit","description":"Human Metallothionein 3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Metallothionein 3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human MT3 in samples. No significant cross-reactivity or interference between Human MT3 and analogues was observed. Innovative Research's Metallothionein 3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human MT3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human MT3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human MT3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human MT3. You can calculate the concentration of Human MT3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Metallothionein 3 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813499252932,"sku":"IHUMT3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_2ca4883b-6da6-4fa3-949a-33692115158a.jpg?v=1740173187"},{"product_id":"human-calcitonin-gene-related-peptide-1-clia-kit","title":"Human Calcitonin Gene Related Peptide 1 Chemiluminescent Immunoassay Kit","description":"Human Calcitonin Gene Related Peptide 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Calcitonin Gene Related Peptide 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CGRP1 in samples. No significant cross-reactivity or interference between Human CGRP1 and analogues was observed. Innovative Research's Calcitonin Gene Related Peptide 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CGRP1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CGRP1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CGRP1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CGRP1. You can calculate the concentration of Human CGRP1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Calcitonin Gene Related Peptide 1 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813499416772,"sku":"IHUCGRP1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_700fb517-d43e-4eac-b33d-32a1fb72faa8.jpg?v=1740173192"},{"product_id":"human-calmodulin-clia-kit","title":"Human Calmodulin Chemiluminescent Immunoassay Kit","description":"Human Calmodulin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Calmodulin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human CAM in samples. No significant cross-reactivity or interference between Human CAM and analogues was observed. Innovative Research's Calmodulin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human CAM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CAM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CAM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CAM. You can calculate the concentration of Human CAM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Calmodulin Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813499646148,"sku":"IHUCAMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_46c8a8c3-5cad-40be-bf00-96f0004f5993.jpg?v=1740173198"}],"url":"https:\/\/www.innov-research.com\/collections\/metabolism.oembed?page=4","provider":"Innovative Research","version":"1.0","type":"link"}