{"title":"Developmental Biology","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eExpand your research in the field of developmental biology with our collection of antibodies, ELISA Kits, CLIA Kits, and more. We carry products that target an extensive range of biomarkers in humans and various animal species.\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e Top researchers and institutions around the world trust our biomarkers and immunoassays to provide fast, accurate, and consistent results. \u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"human-bone-morphogenetic-protein-4-clia-kit","title":"Human Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit","description":"Human Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bone Morphogenetic Protein 4 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human BMP-4 in samples. No significant cross-reactivity or interference between Human BMP-4 and analogues was observed. Innovative Research's Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human BMP-4. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human BMP-4 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human BMP-4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human BMP-4. You can calculate the concentration of Human BMP-4 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bone Morphogenetic Protein 4 Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813469434052,"sku":"IHUBMP4KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_6d8f6b54-56de-49ce-8f86-1c19a3563573.jpg?v=1740172766"},{"product_id":"human-erythropoietin-clia-kit","title":"Human Erythropoietin Chemiluminescent Immunoassay Kit","description":"Human Erythropoietin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Erythropoietin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human EPO in samples. No significant cross-reactivity or interference between Human EPO and analogues was observed. Innovative Research's Erythropoietin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human EPO. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human EPO and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human EPO, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human EPO. You can calculate the concentration of Human EPO in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Erythropoietin Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813474545860,"sku":"IHUEPOKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_e2d1eed6-add9-4106-93f5-5a975b6a479f.jpg?v=1740172831"},{"product_id":"human-insulin-like-growth-factor-1-clia-kit","title":"Human Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay Kit","description":"Human Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin-Like Growth Factor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human IGF-1 in samples. No significant cross-reactivity or interference between Human IGF-1 and analogues was observed. Innovative Research's Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human IGF-1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IGF-1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IGF-1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human IGF-1. You can calculate the concentration of Human IGF-1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin-Like Growth Factor 1 Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813475332292,"sku":"IHUIGF1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_0b8d612a-9f57-4d49-8d7e-629dd9159312.jpg?v=1740172855"},{"product_id":"human-collagen-type-clia-kit","title":"Human Collagen Type ?? Chemiluminescent Immunoassay Kit","description":"Human Collagen Type XIV Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Collagen Type XIV in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human COL14 in samples. No significant cross-reactivity or interference between Human COL14 and analogues was observed. Innovative Research's Collagen Type XIV Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human COL14. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL14 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL14, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human COL14. You can calculate the concentration of Human COL14 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Collagen Type XIV Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813480050884,"sku":"IHUCOL14KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/Powered-By-Molecular-CLIA_2ab26790-bc98-444e-9233-88dfac8d6f44.jpg?v=1740172937"},{"product_id":"human-fibronectin-clia-kit","title":"Human Fibronectin Chemiluminescent Immunoassay Kit","description":"Human Fibronectin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Fibronectin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human FN in samples. No significant cross-reactivity or interference between Human FN and analogues was observed. Innovative Research's Fibronectin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human FN. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FN and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FN, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human FN. You can calculate the concentration of Human FN in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Fibronectin Reactivity: Human Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813480083652,"sku":"IHUFBNKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_0a4ae84a-2315-4e88-87be-0fb8f67c8226.jpg?v=1740172939"},{"product_id":"human-actin-alpha-2-smooth-muscle-clia-kit","title":"Human Actin Alpha 2 Smooth Muscle Chemiluminescent Immunoassay Kit","description":"Human Actin Alpha 2, Smooth Muscle Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Actin Alpha 2, Smooth Muscle in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ACT?2 in samples. No significant cross-reactivity or interference between Human ACT?2 and analogues was observed. Innovative Research's Actin Alpha 2, Smooth Muscle Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ACT?2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ACT?2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ACT?2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ACT?2. You can calculate the concentration of Human ACT?2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Actin Alpha 2, Smooth Muscle Reactivity: Human Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813484376260,"sku":"IHUACTA2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_8f79387e-9097-4762-8e56-1debdf2beeb8.jpg?v=1740172973"},{"product_id":"human-anterior-gradient-protein-2-clia-kit","title":"Human Anterior Gradient Protein 2 Chemiluminescent Immunoassay Kit","description":"Human Anterior Gradient Protein 2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Anterior Gradient Protein 2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human AGR2 in samples. No significant cross-reactivity or interference between Human AGR2 and analogues was observed. Innovative Research's Anterior Gradient Protein 2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human AGR2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGR2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGR2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AGR2. You can calculate the concentration of Human AGR2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Anterior Gradient Protein 2 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813485785284,"sku":"IHUAGR2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_19c90be2-a5a5-45d7-aba7-ccfe95a4af7a.jpg?v=1740172996"},{"product_id":"human-angiopoietin-receptor-tie1-clia-kit","title":"Human Angiopoietin Receptor Tie1 Chemiluminescent Immunoassay Kit","description":"Human Angiopoietin Receptor Tie1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Angiopoietin Receptor Tie1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human ANG-R-Tie1 in samples. No significant cross-reactivity or interference between Human ANG-R-Tie1 and analogues was observed. Innovative Research's Angiopoietin Receptor Tie1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human ANG-R-Tie1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ANG-R-Tie1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ANG-R-Tie1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ANG-R-Tie1. You can calculate the concentration of Human ANG-R-Tie1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Angiopoietin Receptor Tie1 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813486768324,"sku":"IHUANGRTIE1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d0efbddf-d973-42ad-aea2-8d4cff646236.jpg?v=1740173021"},{"product_id":"human-basic-fibroblast-growth-factor-clia-kit","title":"Human Basic Fibroblast Growth Factor Chemiluminescent Immunoassay Kit","description":"Human Basic Fibroblast Growth Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Basic Fibroblast Growth Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human bFGF\/FGF2 in samples. No significant cross-reactivity or interference between Human bFGF\/FGF2 and analogues was observed. Innovative Research's Basic Fibroblast Growth Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human bFGF\/FGF2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human bFGF\/FGF2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human bFGF\/FGF2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human bFGF\/FGF2. You can calculate the concentration of Human bFGF\/FGF2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Basic Fibroblast Growth Factor Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813496238276,"sku":"IHUBFGFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c9106922-4268-46a4-b0cf-d489c5709944.jpg?v=1740173122"},{"product_id":"human-cardiac-troponin-i-clia-kit","title":"Human cardiac Troponin I Chemiluminescent Immunoassay Kit","description":"Human cardiac Troponin I Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring cardiac Troponin I in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human cTn-I\/TNNI3 in samples. No significant cross-reactivity or interference between Human cTn-I\/TNNI3 and analogues was observed. Innovative Research's cardiac Troponin I Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human cTn-I\/TNNI3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human cTn-I\/TNNI3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human cTn-I\/TNNI3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human cTn-I\/TNNI3. You can calculate the concentration of Human cTn-I\/TNNI3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: cardiac Troponin I Reactivity: Human Range: 78.13 - 5000 pg\/mL Sensitivity: 46.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813501907140,"sku":"IHUCTNIKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_bcb71fc1-a62f-4e7a-98ce-56050fc89806.jpg?v=1740173215"},{"product_id":"human-neurofilament-light-polypeptide-clia-kit","title":"Human Neurofilament Light Polypeptide Chemiluminescent Immunoassay Kit","description":"Human Neurofilament, Light Polypeptide Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neurofilament, Light Polypeptide in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NEFL in samples. No significant cross-reactivity or interference between Human NEFL and analogues was observed. Innovative Research's Neurofilament, Light Polypeptide Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NEFL. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NEFL and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NEFL, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NEFL. You can calculate the concentration of Human NEFL in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neurofilament, Light Polypeptide Reactivity: Human Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813503217860,"sku":"IHUNEFLKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_3c31f684-b805-41f8-9383-0a3d73c1cf8f.jpg?v=1740173256"},{"product_id":"human-collagen-type-vi-alpha-3-clia-kit","title":"Human Collagen Type VI Alpha 3 Chemiluminescent Immunoassay Kit","description":"Human Collagen Type VI Alpha 3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Collagen Type VI Alpha 3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human COL6?3 in samples. No significant cross-reactivity or interference between Human COL6?3 and analogues was observed. Innovative Research's Collagen Type VI Alpha 3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human COL6?3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL6?3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL6?3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human COL6?3. You can calculate the concentration of Human COL6?3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Collagen Type VI Alpha 3 Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813507150020,"sku":"IHUCOL6A3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_21a03fb4-569c-4fb9-b9f6-6fbe5039c404.jpg?v=1740173308"},{"product_id":"human-collagen-type-v-alpha-2-clia-kit","title":"Human Collagen Type V Alpha 2 Chemiluminescent Immunoassay Kit","description":"Human Collagen Type V Alpha 2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Collagen Type V Alpha 2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human COL5?2 in samples. No significant cross-reactivity or interference between Human COL5?2 and analogues was observed. Innovative Research's Collagen Type V Alpha 2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human COL5?2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL5?2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL5?2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human COL5?2. You can calculate the concentration of Human COL5?2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Collagen Type V Alpha 2 Reactivity: Human Range: 1.56 - 100 ng\/mL Sensitivity: 0.94 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813508919492,"sku":"IHUCOL5A2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_a62fe190-6ef2-412d-a37e-699c8387ade0.jpg?v=1740173343"},{"product_id":"human-neuron-specific-enolase-clia-kit","title":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit","description":"Human Neuron-Specific Enolase Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Neuron-Specific Enolase in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human NSE in samples. No significant cross-reactivity or interference between Human NSE and analogues was observed. Innovative Research's Neuron-Specific Enolase Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human NSE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NSE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human NSE. You can calculate the concentration of Human NSE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Neuron-Specific Enolase Reactivity: Human Range: 0.47 - 30 ng\/mL Sensitivity: 0.28 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813512458436,"sku":"IHUNSEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_d9adaf8b-5761-49e8-9fa5-e25e66895f52.jpg?v=1740173385"},{"product_id":"human-vimentin-clia-kit","title":"Human Vimentin Chemiluminescent Immunoassay Kit","description":"Human Vimentin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Vimentin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human VIM in samples. No significant cross-reactivity or interference between Human VIM and analogues was observed. Innovative Research's Vimentin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human VIM. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human VIM and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human VIM, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human VIM. You can calculate the concentration of Human VIM in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Vimentin Reactivity: Human Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813513244868,"sku":"IHUVIMKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_10427356-96f1-42e3-b819-9981d44eee10.jpg?v=1740173411"},{"product_id":"human-fibroblast-growth-factor-23-clia-kit","title":"Human Fibroblast Growth Factor 23 Chemiluminescent Immunoassay Kit","description":"Human Fibroblast Growth Factor 23 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Fibroblast Growth Factor 23 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human FGF23 in samples. No significant cross-reactivity or interference between Human FGF23 and analogues was observed. Innovative Research's Fibroblast Growth Factor 23 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human FGF23. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human FGF23 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human FGF23, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human FGF23. You can calculate the concentration of Human FGF23 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Fibroblast Growth Factor 23 Reactivity: Human Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40813513605316,"sku":"IHUFGF23KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_da9dd239-bb52-4b63-a44e-dc45808e9c19.jpg?v=1740173426"},{"product_id":"human-collagen-type-xiii-clia-kit","title":"Human Collagen Type XIII Chemiluminescent Immunoassay Kit","description":"Human Collagen Type XIII Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Collagen Type XIII in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human COL13 in samples. No significant cross-reactivity or interference between Human COL13 and analogues was observed. Innovative Research's Collagen Type XIII Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human COL13. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human COL13 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human COL13, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human COL13. You can calculate the concentration of Human COL13 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Collagen Type XIII Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40823408001220,"sku":"IHUCOL13KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_82fd2d68-5ac9-4694-9bb7-9d153c1b5e5b.jpg?v=1740173504"},{"product_id":"human-platelet-derived-growth-factor-bb-clia-kit","title":"Human Platelet Derived Growth Factor-BB Chemiluminescent Immunoassay Kit","description":"Human Platelet Derived Growth Factor-BB Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Platelet Derived Growth Factor-BB in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human PDGF-BB in samples. No significant cross-reactivity or interference between Human PDGF-BB and analogues was observed. Innovative Research's Platelet Derived Growth Factor-BB Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human PDGF-BB. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human PDGF-BB and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human PDGF-BB, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human PDGF-BB. You can calculate the concentration of Human PDGF-BB in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Platelet Derived Growth Factor-BB Reactivity: Human Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863001968836,"sku":"IHUPDGFBBKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_ff5f1dcc-0338-4d95-b3b4-6bcee3c35bb2.jpg?v=1740173717"},{"product_id":"human-glypican-3-clia-kit","title":"Human Glypican 3 Chemiluminescent Immunoassay Kit","description":"Human Glypican 3 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glypican 3 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Human GPC3 in samples. No significant cross-reactivity or interference between Human GPC3 and analogues was observed. Innovative Research's Glypican 3 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Human GPC3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GPC3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GPC3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human GPC3. You can calculate the concentration of Human GPC3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glypican 3 Reactivity: Human Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863015076036,"sku":"IHUGPC3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_f26e4b65-09dd-4a19-b764-f1e90d159492.jpg?v=1740173785"},{"product_id":"mouse-growth-hormone-clia-kit","title":"Mouse Growth Hormone Chemiluminescent Immunoassay Kit","description":"Mouse Growth Hormone Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Growth Hormone in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse GH in samples. No significant cross-reactivity or interference between Mouse GH and analogues was observed. Innovative Research's Growth Hormone Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse GH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse GH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse GH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse GH. You can calculate the concentration of Mouse GH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Growth Hormone Reactivity: Mouse Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863076647108,"sku":"IMSGHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_a254bfde-b76f-42dc-9ad4-caf985f98ed2.jpg?v=1740174183"},{"product_id":"mouse-anti-mullerian-hormone-clia-kit","title":"Mouse Anti-Mullerian Hormone Chemiluminescent Immunoassay Kit","description":"Mouse Anti-Mullerian Hormone Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Anti-Mullerian Hormone in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse AMH in samples. No significant cross-reactivity or interference between Mouse AMH and analogues was observed. Innovative Research's Anti-Mullerian Hormone Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse AMH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse AMH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse AMH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse AMH. You can calculate the concentration of Mouse AMH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Anti-Mullerian Hormone Reactivity: Mouse Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863081464004,"sku":"IMSAMHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_c3ec57c0-cfe1-4e92-b04e-49854e45f551.jpg?v=1740174216"},{"product_id":"mouse-apolipoprotein-e-clia-kit","title":"Mouse Apolipoprotein E Chemiluminescent Immunoassay Kit","description":"Mouse Apolipoprotein E Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein E in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse APO-E in samples. No significant cross-reactivity or interference between Mouse APO-E and analogues was observed. Innovative Research's Apolipoprotein E Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse APO-E. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse APO-E and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse APO-E, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse APO-E. You can calculate the concentration of Mouse APO-E in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein E Reactivity: Mouse Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863082676420,"sku":"IMSAPOEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_8701ef1a-9d30-40fe-a87e-6e4142cdece5.jpg?v=1740174221"},{"product_id":"mouse-bone-morphogenetic-protein-4-clia-kit","title":"Mouse Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit","description":"Mouse Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bone Morphogenetic Protein 4 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse BMP-4 in samples. No significant cross-reactivity or interference between Mouse BMP-4 and analogues was observed. Innovative Research's Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse BMP-4. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse BMP-4 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse BMP-4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse BMP-4. You can calculate the concentration of Mouse BMP-4 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bone Morphogenetic Protein 4 Reactivity: Mouse Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40863087329476,"sku":"IMSBMP4KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_5f4461dd-a076-40a7-ad32-e45b6c2f931a.jpg?v=1740174261"},{"product_id":"mouse-e-cadherin-clia-kit","title":"Mouse E-Cadherin Chemiluminescent Immunoassay Kit","description":"Mouse E-Cadherin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring E-Cadherin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse E-Cad in samples. No significant cross-reactivity or interference between Mouse E-Cad and analogues was observed. Innovative Research's E-Cadherin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse E-Cad. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse E-Cad and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse E-Cad, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse E-Cad. You can calculate the concentration of Mouse E-Cad in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: E-Cadherin Reactivity: Mouse Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904646623428,"sku":"IMSECADKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_b0eb66cc-1840-4a6f-b417-3e31cb9207e8.jpg?v=1740174267"},{"product_id":"mouse-glial-cell-line-derived-neurotrophic-factor-clia-kit","title":"Mouse Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay Kit","description":"Mouse Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glial Cell Line Derived Neurotrophic Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse GDNF in samples. No significant cross-reactivity or interference between Mouse GDNF and analogues was observed. Innovative Research's Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse GDNF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse GDNF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse GDNF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse GDNF. You can calculate the concentration of Mouse GDNF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glial Cell Line Derived Neurotrophic Factor Reactivity: Mouse Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904669724868,"sku":"IMSGDNFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_8275a918-24ec-4ca7-85cb-7144384d61f2.jpg?v=1740174372"},{"product_id":"mouse-osteonectin-clia-kit","title":"Mouse Osteonectin Chemiluminescent Immunoassay Kit","description":"Mouse Osteonectin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Osteonectin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse ON in samples. No significant cross-reactivity or interference between Mouse ON and analogues was observed. Innovative Research's Osteonectin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse ON. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse ON and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse ON, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse ON. You can calculate the concentration of Mouse ON in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Osteonectin Reactivity: Mouse Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904706982084,"sku":"IMSONKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_e2ff74d7-77c5-456c-8e02-8e3f0369b630.jpg?v=1740174487"},{"product_id":"mouse-troponin-i-type-3-cardiac-clia-kit","title":"Mouse Troponin I Type 3 Cardiac Chemiluminescent Immunoassay Kit","description":"Mouse Troponin I Type 3, Cardiac Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Troponin I Type 3, Cardiac in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Mouse TNNI3\/cTn-I in samples. No significant cross-reactivity or interference between Mouse TNNI3\/cTn-I and analogues was observed. Innovative Research's Troponin I Type 3, Cardiac Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Mouse TNNI3\/cTn-I. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse TNNI3\/cTn-I and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse TNNI3\/cTn-I, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Mouse TNNI3\/cTn-I. You can calculate the concentration of Mouse TNNI3\/cTn-I in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Troponin I Type 3, Cardiac Reactivity: Mouse Range: 3.13 - 200 pg\/mL Sensitivity: 1.88 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904721498308,"sku":"IMSTNNI3KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_19508749-3839-4156-888a-5091c789c056.jpg?v=1740174559"},{"product_id":"rat-insulin-like-growth-factor-1-clia-kit","title":"Rat Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay Kit","description":"Rat Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Insulin-Like Growth Factor 1 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat IGF-1 in samples. No significant cross-reactivity or interference between Rat IGF-1 and analogues was observed. Innovative Research's Insulin-Like Growth Factor 1 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat IGF-1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IGF-1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IGF-1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat IGF-1. You can calculate the concentration of Rat IGF-1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Insulin-Like Growth Factor 1 Reactivity: Rat Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904729329860,"sku":"IRTIGF1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_b8fd5f0b-e727-4af0-b7bc-73fe153b375c.jpg?v=1740174591"},{"product_id":"rat-microalbuminuria-clia-kit","title":"Rat Microalbuminuria Chemiluminescent Immunoassay Kit","description":"Rat Microalbuminuria Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Microalbuminuria in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat MAU in samples. No significant cross-reactivity or interference between Rat MAU and analogues was observed. Innovative Research's Microalbuminuria Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat MAU. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat MAU and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat MAU, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat MAU. You can calculate the concentration of Rat MAU in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Microalbuminuria Reactivity: Rat Range: 0.31 - 20 ug\/mL Sensitivity: 0.19 ug\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904730181828,"sku":"IRTMAUKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_0d0c4a69-7ed0-4b61-b4d1-206c4d7190e9.jpg?v=1740174599"},{"product_id":"rat-growth-hormone-clia-kit","title":"Rat Growth Hormone Chemiluminescent Immunoassay Kit","description":"Rat Growth Hormone Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Growth Hormone in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat GH in samples. No significant cross-reactivity or interference between Rat GH and analogues was observed. Innovative Research's Growth Hormone Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat GH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat GH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat GH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat GH. You can calculate the concentration of Rat GH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Growth Hormone Reactivity: Rat Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904730607812,"sku":"IRTGHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_77e9b63b-68af-4467-afd6-d012659abc03.jpg?v=1740174602"},{"product_id":"rat-bone-morphogenetic-protein-4-clia-kit","title":"Rat Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit","description":"Rat Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Bone Morphogenetic Protein 4 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat BMP-4 in samples. No significant cross-reactivity or interference between Rat BMP-4 and analogues was observed. Innovative Research's Bone Morphogenetic Protein 4 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat BMP-4. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat BMP-4 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat BMP-4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat BMP-4. You can calculate the concentration of Rat BMP-4 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Bone Morphogenetic Protein 4 Reactivity: Rat Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40904739127492,"sku":"IRTBMP4KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_806b2dc9-700b-40ce-83cb-176c6df1cc4e.jpg?v=1740174633"},{"product_id":"rat-glial-cell-line-derived-neurotrophic-factor-clia-kit","title":"Rat Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay Kit","description":"Rat Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Glial Cell Line Derived Neurotrophic Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat GDNF in samples. No significant cross-reactivity or interference between Rat GDNF and analogues was observed. Innovative Research's Glial Cell Line Derived Neurotrophic Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat GDNF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat GDNF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat GDNF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat GDNF. You can calculate the concentration of Rat GDNF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Glial Cell Line Derived Neurotrophic Factor Reactivity: Rat Range: 15.63 - 1000 pg\/mL Sensitivity: 9.38 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945484038340,"sku":"IRTGDNFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_e9aac2ea-eccb-4ca1-a8ed-5d72b90c7c3d.jpg?v=1740174742"},{"product_id":"rat-sonic-hedgehog-protein-clia-kit","title":"Rat Sonic Hedgehog Protein Chemiluminescent Immunoassay Kit","description":"Rat Sonic Hedgehog Protein Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Sonic Hedgehog Protein in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat SHH in samples. No significant cross-reactivity or interference between Rat SHH and analogues was observed. Innovative Research's Sonic Hedgehog Protein Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat SHH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat SHH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat SHH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat SHH. You can calculate the concentration of Rat SHH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Sonic Hedgehog Protein Reactivity: Rat Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945485316292,"sku":"IRTSHHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_7cd6a1ad-7c51-4de9-ae55-81feadeaa9d2.jpg?v=1740174765"},{"product_id":"rat-platelet-derived-growth-factor-bb-clia-kit","title":"Rat Platelet-Derived Growth Factor-BB Chemiluminescent Immunoassay Kit","description":"Rat Platelet-Derived Growth Factor-BB Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Platelet-Derived Growth Factor-BB in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat PDGF-BB in samples. No significant cross-reactivity or interference between Rat PDGF-BB and analogues was observed. Innovative Research's Platelet-Derived Growth Factor-BB Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat PDGF-BB. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat PDGF-BB and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat PDGF-BB, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat PDGF-BB. You can calculate the concentration of Rat PDGF-BB in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Platelet-Derived Growth Factor-BB Reactivity: Rat Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945486299332,"sku":"IRTPDGFBBKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_a2c5cd23-4c9f-4285-b448-e219c2ba3791.jpg?v=1740174789"},{"product_id":"rat-fibronectin-clia-kit","title":"Rat Fibronectin Chemiluminescent Immunoassay Kit","description":"Rat Fibronectin Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Fibronectin in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat FN in samples. No significant cross-reactivity or interference between Rat FN and analogues was observed. Innovative Research's Fibronectin Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat FN. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat FN and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat FN, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat FN. You can calculate the concentration of Rat FN in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Fibronectin Reactivity: Rat Range: 0.31 - 20 ng\/mL Sensitivity: 0.19 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945487085764,"sku":"IRTFBNKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_fbac6985-c516-479d-a308-1dd3328ee6f1.jpg?v=1740174807"},{"product_id":"rat-anti-mullerian-hormone-clia-kit","title":"Rat Anti-Mullerian Hormone Chemiluminescent Immunoassay Kit","description":"Rat Anti-Mullerian Hormone Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Anti-Mullerian Hormone in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat AMH in samples. No significant cross-reactivity or interference between Rat AMH and analogues was observed. Innovative Research's Anti-Mullerian Hormone Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat AMH. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat AMH and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat AMH, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat AMH. You can calculate the concentration of Rat AMH in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Anti-Mullerian Hormone Reactivity: Rat Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945488462020,"sku":"IRTAMHKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_552859c1-e448-4d01-99e2-faf6d8725632.jpg?v=1740174835"},{"product_id":"rat-runt-related-transcription-factor-2-clia-kit","title":"Rat Runt Related Transcription Factor 2 Chemiluminescent Immunoassay Kit","description":"Rat Runt Related Transcription Factor 2 Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Runt Related Transcription Factor 2 in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat RUNX2 in samples. No significant cross-reactivity or interference between Rat RUNX2 and analogues was observed. Innovative Research's Runt Related Transcription Factor 2 Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat RUNX2. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat RUNX2 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat RUNX2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat RUNX2. You can calculate the concentration of Rat RUNX2 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Runt Related Transcription Factor 2 Reactivity: Rat Range: 62.5 - 4000 pg\/mL Sensitivity: 37.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945494098116,"sku":"IRTRUNX2KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_4b14fdbc-144b-425b-a228-0480a4657131.jpg?v=1740174883"},{"product_id":"rat-selenoprotein-p-clia-kit","title":"Rat Selenoprotein P Chemiluminescent Immunoassay Kit","description":"Rat Selenoprotein P Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Selenoprotein P in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat SEPP1 in samples. No significant cross-reactivity or interference between Rat SEPP1 and analogues was observed. Innovative Research's Selenoprotein P Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat SEPP1. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat SEPP1 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat SEPP1, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat SEPP1. You can calculate the concentration of Rat SEPP1 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Selenoprotein P Reactivity: Rat Range: 31.25 - 2000 pg\/mL Sensitivity: 18.75 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945497571524,"sku":"IRTSEPP1KTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_e1e58df6-a3b2-4c6f-b5e5-f98af1ca94e0.jpg?v=1740174887"},{"product_id":"rat-stem-cell-factor-clia-kit","title":"Rat Stem Cell Factor Chemiluminescent Immunoassay Kit","description":"Rat Stem Cell Factor Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Stem Cell Factor in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat SCF in samples. No significant cross-reactivity or interference between Rat SCF and analogues was observed. Innovative Research's Stem Cell Factor Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat SCF. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat SCF and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat SCF, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat SCF. You can calculate the concentration of Rat SCF in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Stem Cell Factor Reactivity: Rat Range: 7.81 - 500 pg\/mL Sensitivity: 4.69 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945497931972,"sku":"IRTSCFKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_cb24c0ea-be2b-4746-b6fc-9439b00a247e.jpg?v=1740174895"},{"product_id":"rat-apolipoprotein-e-clia-kit","title":"Rat Apolipoprotein E Chemiluminescent Immunoassay Kit","description":"Rat Apolipoprotein E Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Apolipoprotein E in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat ApoE in samples. No significant cross-reactivity or interference between Rat ApoE and analogues was observed. Innovative Research's Apolipoprotein E Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat ApoE. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat ApoE and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat ApoE, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat ApoE. You can calculate the concentration of Rat ApoE in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Apolipoprotein E Reactivity: Rat Range: 0.63 - 40 ng\/mL Sensitivity: 0.38 ng\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945506058436,"sku":"IRTAPOEKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_168fc375-7d69-4d59-ab0a-a9fbe7691ca3.jpg?v=1740174953"},{"product_id":"rat-cardiac-troponin-i-clia-kit","title":"Rat Cardiac Troponin I Chemiluminescent Immunoassay Kit","description":"Rat Cardiac Troponin I Chemiluminescent Immunoassay Kit from Innovative Research is a highly sensitive Chemiluminescent Immunoassay for meauring Cardiac Troponin I in biofluid samples, such as serum, plasma and other biological fluids. Reagents for up to 96 tests. This assay recognizes Rat cTn-I\/TNNI3 in samples. No significant cross-reactivity or interference between Rat cTn-I\/TNNI3 and analogues was observed. Innovative Research's Cardiac Troponin I Chemiluminescent Immunoassay kit uses the Sandwich-Chemiluminescent Immunoassay principle. The micro Chemiluminescent Immunoassay plate provided in this kit has been pre-coated with an antibody specific to Rat cTn-I\/TNNI3. Standards or samples are added to the micro Chemiluminescent Immunoassay plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat cTn-I\/TNNI3 and Avidin-Horseradish Peroxidase(HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat cTn-I\/TNNI3, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit(RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat cTn-I\/TNNI3. You can calculate the concentration of Rat cTn-I\/TNNI3 in the samples by comparing the RLU value of the samples to the standard curve. Detection Target: Cardiac Troponin I Reactivity: Rat Range: 12.5 - 800 pg\/mL Sensitivity: 7.5 pg\/mL Storage Conditions: An unopened kit can be stored at 2-8 C for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received For research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":40945506353348,"sku":"IRTCTNIKTC","price":572.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/products\/CLIA-Product-Image_360x_0f7ea6af-9d2d-42a2-a74a-b197795acbb9.jpg?v=1740174955"},{"product_id":"mouse-anti-human-eno2-monoclonal-clone-2k3","title":"Mouse Anti Human ENO2 Monoclonal Clone 2K3","description":"\u003cp\u003eMouse Anti Human ENO2 Monoclonal Clone 2K3 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide and 50% glycerol pH 7.4. This antibody has been purified using Protein A purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e ENO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Synthetic Peptide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHas neurotrophic and neuroprotective properties on a broad spectrum of central nervous system (CNS) neurons. Binds, in a calcium-dependent manner, to cultured neocortical neurons and promotes cell survival\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as Western Blot,IHC-p,Immunofluorescence.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966242336964,"sku":"IMSAMLENO22K3C120UL","price":276.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_27dcfd02-87d9-4434-bbe2-74725af0fcbd.jpg?v=1740083872"},{"product_id":"mouse-anti-human-nes-monoclonal-clone-1a12d12","title":"Mouse Anti Human NES Monoclonal Clone 1A12D12","description":"\u003cp\u003eMouse Anti Human NES Monoclonal Clone 1A12D12 from Innovative Research is a monoclonal antibody in a liquid format, buffered in PBS with 0.02% sodium azide, 1% BSA and 50% glycerol, pH7.4 This antibody has been purified using Affinity purification.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost:\u003c\/b\u003e Mouse\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human,Mouse,Rat\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e NES\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClonality:\u003c\/b\u003e Monoclonal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eImmunogen:\u003c\/b\u003e Recombinant protein corresponding to Mouse Nestin\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at -20°C. Avoid freeze \/ thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNestin,also named as NES and Nbla00170,is a class VI intermediate filament protein expressed in stem cells of the central nervous system (CNS) but not in mature CNS cells. Its expression is used extensively as a marker for neural lineage cells derived from human embryonic stem (hES) and induced pluripotent stem (iPS) cells. Nestin is also expressed in non-neural stem cell populations such as pancreatic islet progenitors and hematopoietic progenitors.\u003c\/p\u003e\u003cp\u003eThis product can be used in analytical tools such as IHC.\u003c\/p\u003e\u003cp\u003eAt Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e\u003cp\u003eFor research use only.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"120ul","offer_id":40966243811524,"sku":"IMSAMLNES1A12D12C120UL","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/734844f0-9525-4b33-ad45-0c859a90882c_84ae8cd8-0427-4d6b-a924-56ba91018cd3.jpg?v=1740083891"},{"product_id":"fgfr2-active-recombinant-protein-n-his-gst-tag","title":"FGFR2 Active Recombinant Protein N-His \u0026 GST Tag","description":"\u003cp\u003eFGFR2 Active Recombinant Protein N-His \u0026amp; GST Tag from Innovative Research has been recombinantly produced in Baculovirus-Insect Cells. The protein formulation is supplied as sterile 20mM Tris, 500mM NaCl, pH 7.4, 10% gly with a purity of \u0026gt; 92 % as determined by reducing SDS-PAGE.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003ci\u003eMore Details:\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSpecies:\u003c\/b\u003e Human\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTarget:\u003c\/b\u003e FGFR2\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePurity:\u003c\/b\u003e \u0026gt; 92 % as determined by reducing SDS-PAGE. \u0026lt; 1.0 EU per µg as determined by the LAL method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSource:\u003c\/b\u003e Baculovirus-Insect Cells\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Conditions:\u003c\/b\u003e Store at \u0026lt; -20°C, stable for 6 months. Please minimize freeze-thaw cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis product is provided as liquid. It is shipped at frozen temperature with blue ice\/gel packs. Upon receipt, store it immediately at\u0026lt;-20C.\u003c\/p\u003e\u003cp\u003eFor research use only. At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.\u003c\/p\u003e","brand":"Innovative Research","offers":[{"title":"50ug","offer_id":42109242572996,"sku":"IHUFGFR2ARNHISGST50UG","price":863.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/66211b8b-ccf5-459c-bd40-6ec9ff2c4d10_fa292cf3-da92-4255-bfdb-f25f09bae974.jpg?v=1740024184"},{"product_id":"mouse-apoe-elisa-kit","title":"Mouse ApoE ELISA Kit","description":"Mouse ApoE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring ApoE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Mouse ApoE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse ApoE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse ApoE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Mouse ApoE. You can calculate the concentration of Mouse ApoE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: ApoE Reactivity: Mouse Range: 1.56 - 100ng\/mL Sensitivity: 0.94ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236033994948,"sku":"IMSAPOEKT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_096400a7-ef5e-46df-9569-62054c8159d9.jpg?v=1739978545"},{"product_id":"rat-apoe-elisa-kit","title":"Rat ApoE ELISA Kit","description":"Rat ApoE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring ApoE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rat ApoE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat ApoE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat ApoE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rat ApoE. You can calculate the concentration of Rat ApoE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: ApoE Reactivity: Rat Range: 3.13 - 200ng\/mL Sensitivity: 1.88ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236034060484,"sku":"IRTAPOEKT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_572bff28-3bda-44e1-b37e-093058a3af7e.jpg?v=1739978545"},{"product_id":"rabbit-bfgffgf2-elisa-kit","title":"Rabbit bFGF\/FGF2 ELISA Kit","description":"Rabbit bFGF\/FGF2 Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring bFGF\/FGF2 in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Rabbit bFGF\/FGF2. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rabbit bFGF\/FGF2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rabbit bFGF\/FGF2, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Rabbit bFGF\/FGF2. You can calculate the concentration of Rabbit bFGF\/FGF2 in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: bFGF\/FGF2 Reactivity: Rabbit Range: 15.63 - 1000pg\/mL Sensitivity: 9.38pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236036845764,"sku":"IRBBFGFFGF2KT","price":645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_902eaa4b-4de4-4ea8-aa11-dcb2df339715.jpg?v=1739978569"},{"product_id":"humanmonkeymouse-e2-elisa-kit","title":"Human\/MonKey\/Mouse E2 ELISA Kit","description":"Human\/MonKey\/Mouse E2 Competitive ELISA Kit from Innovative Research is a highly sensitive competitive enzyme-linked immunoassay (Competitive ELISA) for measuring E2 in serum, plasma, urine, and saliva. Reagents for up to 96 tests.This Competitive ELISA Kit uses the Competitive-Competitive ELISA principle. The micro Competitive ELISA plate provided in this Kit has been pre-coated with Human\/MonKey\/Mouse E2. During the reaction, Human\/MonKey\/Mouse E2 in samples or Standard competes with a fixed amount of Human\/MonKey\/Mouse E2 on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human\/MonKey\/Mouse E2. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The concentration of Human\/MonKey\/Mouse E2 in the samples is then determined by comparing the OD of the samples to the standard curve.More Details: Detection Target: E2 Reactivity: Human\/MonKey\/Mouse Range: 9.37 - 600pg\/mL Sensitivity: 5.63pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236050608324,"sku":"IHUMNMSE2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/500DAssaysImage_47e79017-9d4f-4874-a419-ee16a44493fb.png?v=1741290786"},{"product_id":"ratporcine-e2-elisa-kit","title":"Rat\/Porcine E2 ELISA Kit","description":"Rat\/Porcine E2 Competitive ELISA Kit from Innovative Research is a highly sensitive competitive enzyme-linked immunoassay (Competitive ELISA) for measuring E2 in serum and plasma. Reagents for up to 96 tests.This Competitive ELISA Kit uses the Competitive-Competitive ELISA principle. The micro Competitive ELISA plate provided in this Kit has been pre-coated with Rat\/Porcine E2. During the reaction, Rat\/Porcine E2 in samples or Standard competes with a fixed amount of Rat\/Porcine E2 on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Rat\/Porcine E2. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The concentration of Rat\/Porcine E2 in the samples is then determined by comparing the OD of the samples to the standard curve.More Details: Detection Target: E2 Reactivity: Rat\/Porcine Range: 1.56 - 100pg\/mL Sensitivity: 1.00pg\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236050804932,"sku":"IRTPCE2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_db275bef-c247-4d9c-b5b8-047347d41314.jpg?v=1739978694"},{"product_id":"human-nse-elisa-kit","title":"Human NSE ELISA Kit","description":"Human NSE Sandwich ELISA Kit from Innovative Research is a highly sensitive sandwich enzyme-linked immunoassay (Sandwich ELISA) for measuring NSE in serum, plasma and other biological fluids. Reagents for up to 96 tests.This Sandwich ELISA Kit uses the Sandwich-Sandwich ELISA principle. The micro Sandwich ELISA plate provided in this Kit has been pre-coated with an antibody specific to Human NSE. Samples (or Standards) are added to the micro Sandwich ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human NSE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human NSE, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ▒ 2 nm. The OD value is proportional to the concentration of Human NSE. You can calculate the concentration of Human NSE in the samples by comparing the OD of the samples to the standard curve.More Details: Detection Target: NSE Reactivity: Human Range: 2.34 - 150ng\/mL Sensitivity: 1.4ng\/mL Storage Conditions: An unopened kit can be stored at 2 - 8 ░C for 1 month unless otherwise specified in the kit documetation. If the kit is not supposed to be used within 1 month, store the components separately upon receipt according to the directions accompanying the kit., At Innovative Research, we provide reliable, consistent products that deliver reliable, consistent results.For research use only. \u003cbr\u003e\u003ca href=\"https:\/\/youtu.be\/J7fuMk6JfyI?si=cvhwIRlxjJlTCI3m\"\u003eClick here\u003c\/a\u003e to view a video tutorial covering frequently asked questions regarding ELISA workflows.","brand":"Innovative Research","offers":[{"title":"Default Title","offer_id":41236051984580,"sku":"IHUENO2KT","price":468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/files\/8044494f-a574-4da9-a905-b780d80c69bf_954e24c7-812c-40fa-bb5f-6ee1abab8b70.jpg?v=1739978704"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/2297\/4065\/collections\/Products_257ab04f-52d7-497c-baeb-1cc632c5f0c6.png?v=1646679168","url":"https:\/\/www.innov-research.com\/collections\/developmental-biology.oembed?page=3","provider":"Innovative Research","version":"1.0","type":"link"}